Rapid online deep artifact suppression for real-time spiral bSSFP CMR with blipped-CAIPI simultaneous multi-slice imaging at 1.5 T

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Purpose: Real-time (RT) bSSFP MRI enables fast free-breathing cardiovascular imaging but requires 10-16 slices for functional assessment, resulting in prolonged scan times. Simultaneous multi-slice (SMS) imaging can reduce acquisition time but when combined with non-Cartesian trajectories, it relies on iterative reconstructions that preclude online use. This study investigates deep artifact suppression to facilitate rapid, online reconstruction of RT-SMS. Methods: A spiral bSSFP SMS RT sequence with two simultaneously acquired slices was implemented at 1.5 T. Reconstruction used slice separation in k-space, followed by deep artifact suppression in image space using a 3D U-Net. Ten healthy volunteers were imaged. RT-SMS image quality and reconstruction time were compared between deep artifact suppression and compressed sensing (CS) reconstructions. Left (LV) and right (RV) ventricular volumes at end diastole (EDV) and end systole (ESV) and LV mass (LVM) were compared between RT-SMS with deep artifact suppression and reference-standard breath-hold (BH) imaging. Results: The RT-SMS acquisition was ~13x faster than BH imaging (15 s vs 3 min 15 s). RT-SMS reconstruction using deep artifact suppression was ~50x faster than CS (30 s vs 24 min 55 s). Deep artifact suppression consistently outperformed CS in quantitative and qualitative image quality (p<0.001). Functional agreement between BH and RT-SMS with deep artifact suppression was good (LVEDV: -7.5 +/- 6.8 ml, LVESV: -0.9 +/- 4.2 ml, RVEDV: -6.4 +/- 8.4 ml, RVESV: 0.2 +/- 10.7 ml, LVM: -10.3 +/- 11.0 g). Conclusion: Online deep artifact suppression reconstruction for RT-SMS bSSFP CMR enables free-breathing short-axis coverage with a substantial reduction in acquisition and reconstruction time while maintaining diagnostic image quality.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les sujets associés

Advanced MRI Techniques and ApplicationsCardiac Imaging and DiagnosticsLanthanide and Transition Metal Complexes

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.