Aller au contenu principal
Accès ouvert déclaré 2026 preprint

Determinants of specificity and end-user acceptability of an IP-10-based point-of-care triage test for antiretroviral therapy monitoring in Mozambique

0Citations signalées — pas une note de qualité
9Institutions déclarées
4Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Introduction Viral load (VL) monitoring is the gold standard for antiretroviral therapy (ART) monitoring. Still, due to limited funds and infrastructure, many people living with HIV (PLHIV) in low– and middle-income countries do not receive timely VL testing. We evaluated the clinical performance and end-user acceptability of a prototype interferon gamma-induced protein 10 (IP-10) point-of-care (POC) test as a rule-out triage tool to identify individuals unlikely to have unsuppressed VL in PLHIV in Mozambique. Methods A mixed-methods study was conducted between November 2023 and November 2024 at two primary healthcare facilities in Maputo Province. We enrolled 1,057 PLHIV on ART from stable and specialized risk clinics. Clinical performance of the IP-10 POC test (index test) was compared against plasma HIV VL (reference test; unsuppressed defined as >1000 copies/mL). Socio-demographic and clinical predictors of false-positive results were identified using multivariable logistic regression. Immediate acceptability was assessed through exit interviews on a subset of 43 PLHIV. Results Among participants (71.7% female; median age 41.4 years), 12.0% had unsuppressed VL. The IP-10 POC test demonstrated high sensitivity (90.6%) and moderate specificity (35.6%). Specificity was higher in clinics treating stable patients (44.5% 95%CI: 39.7−49.3) compared to specialized risk clinics (26.5% 95%CI: 21.1−28.9). The proportion of false-positive results was also higher in patients attending specialized risk clinics. Independent predictors of false positivity included enrolment in a “one-stop” TB/HIV clinic (aOR=2.99 95%CI: 1.09−8.15), cotrimoxazole use (aOR=2.16, 95% CI: 1.13−4.13), and obesity (aOR=3.47 95%CI: 1.74−6.93). Acceptability was high: 70% of participants appreciated the test’s simplicity and rapid results, and 95.3% expressed interest in future testing. Most patients preferred finger-prick collection over venous draws. Conclusions The IP-10 POC test is a highly sensitive triage tool, demonstrating superior performance among stable PLHIV enrolled in differentiated service delivery models like six-month multi-month dispensing. While factors associated with co-infections can reduce specificity, the test’s high acceptability and potential to reduce confirmatory VL test demand suggests it could serve as a viable triage strategy for optimizing resources particularly in stable care pathways with a lower prevalence of inflammatory comorbidities. This could enable health systems to reallocate intensive monitoring toward higher-risk populations.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Determinants of specificity and end-user acceptability of an IP-10-based point-of-care triage test for antiretroviral therapy monitoring in Mozambique
Date Crossref
24/05/2026
Éditeur
openRxiv
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

HIV/AIDS Research and InterventionsTuberculosis Research and EpidemiologyRespiratory viral infections research

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.