Aller au contenu principal
Accès ouvert déclaré 2026 article

MRIgRT real-time target tracking: TrackRAD2025 challenge report

1Citations signalées — pas une note de qualité
33Institutions déclarées
9Pays d’affiliation déclarés

Résumé fourni par la source

Magnetic resonance imaging (MRI)-guided radiotherapy (MRIgRT) integrates MRI with linear accelerators (MRI-linacs), enabling real-time motion management based on temporally resolved 2D MRI (cine-MRI). Current systems rely on template matching or deformable image registration for radiotherapy target (typically the gross tumor volume) localization, which allows beam gating. Further advances in localization could support more precise and efficient delivery methods. https://trackrad2025.grand-challenge.org/ was organized to provide a common dataset to benchmark algorithms for MRIgRT target tracking in 2D+t cine-MRI. Participants propagated target segmentation masks from an initialization frame across subsequent frames. The dataset comprised sagittal cine-MRI scans of 585 cancer patients undergoing radiotherapy at 0.35 T and 1.5 T MRI-linacs at six different institutions, with expert-annotated targets in 108 sequences. Target sites included the thorax (179 cases), abdomen (266 cases), and pelvis (140 cases). A total of 477 unlabeled and 50 labeled cases were provided for training purposes, 58 cases were kept private for preliminary testing (8) and final evaluation (50). The algorithms submitted by participants were executed on the challenge platform and assessed using metrics in three categories: geometric accuracy, surrogate dose accuracy and execution speed. Rankings were derived via a Rank-Then-Mean scheme. TrackRAD2025 attracted 148 registrations from 28 countries, 100 preliminary submissions and 24 final submissions from 14 teams. The top five methods achieved mean Dice similarity coefficients >0.87 and Euclidean center distances <2.1 mm, comparable to interobserver variability. Leading top five solutions featured foundation models with (4) or without (1) finetuning. Field strength had minimal effect on performance and tracking worked better for the pelvis with reduced motion amplitude compared to the thorax and abdomen cases, which achieved equivalent performance. TrackRAD2025 established a benchmark for MRIgRT tracking on multi-institutional cine-MRI data, highlighting foundation models as promising for clinical translation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
MRIgRT real-time target tracking: TrackRAD2025 challenge report
Date Crossref
01/07/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Medical Image Segmentation TechniquesTarget Tracking and Data Fusion in Sensor NetworksVideo Surveillance and Tracking Methods

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.