Does Dynamic Compliance-Guided PEEP Titration Reduce Postoperative Pulmonary Aeration Loss in Laparoscopic Bariatric Surgery? Randomized Controlled Trial

1Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : tr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background and Objectives: Patients with obesity undergoing laparoscopic bariatric surgery face elevated perioperative pulmonary risk due to impaired respiratory mechanics, reduced functional residual capacity, and pneumoperitoneum-induced atelectasis. Intraoperative changes in intra-abdominal pressure and surgical positioning substantially alter respiratory mechanics, yet studies evaluating repeated PEEP titration at multiple intraoperative time points remain limited. This study aimed to determine whether dynamic compliance-guided individualized PEEP titration, applied at three distinct intraoperative stages, reduces postoperative pulmonary aeration loss compared to fixed 8 cmH2O PEEP. Methods: In this single-center randomized controlled trial with blinded outcome assessment, 70 patients with obesity (BMI ≥ 35 kg/m2) undergoing laparoscopic bariatric surgery were randomized 1:1 to the CDYN group (dynamic compliance-guided PEEP titration at T1: post-induction, T2: during pneumoperitoneum, T3: post-deflation; n = 35) or the PEEP8 group (fixed PEEP 8 cmH2O; n = 35). The primary outcome was the modified lung ultrasound score (mLUSS), assessed 30 min after PACU arrival by a blinded investigator (ClinicalTrials.gov: NCT06994780). Results: Total mLUSS was significantly lower in the CDYN group (2.20 ± 1.16 vs. 5.80 ± 2.14; p < 0.001), with significant differences in both hemithoraces. The PaO2/FiO2 ratio at PACU was significantly higher in the CDYN group (425.11 ± 127.13 vs. 311.65 ± 92.59 mmHg; p < 0.001), and the supplemental oxygen requirement was significantly lower (p = 0.001). Dynamic compliance was consistently higher throughout surgery (all p < 0.001) without differences in airway pressures or hemodynamics. Conclusions: Dynamic compliance-guided individualized PEEP titration, applied at three intraoperative stages, significantly reduces early postoperative pulmonary aeration loss and improves oxygenation in patients with obesity undergoing laparoscopic bariatric surgery, without increasing barotrauma risk or hemodynamic instability.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Does Dynamic Compliance-Guided PEEP Titration Reduce Postoperative Pulmonary Aeration Loss in Laparoscopic Bariatric Surgery? Randomized Controlled Trial
Date Crossref
22/05/2026
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Abdominal Surgery and ComplicationsRespiratory Support and MechanismsHemodynamic Monitoring and Therapy

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.