Aller au contenu principal
Accès ouvert déclaré 2026 article

Ultrasound-guided high-intensity focused ultrasound is technically feasible and safe for occluding placental vessels in early-onset twin-twin transfusion syndrome

1Citations signalées, ce qui n’est pas une note de qualité
7Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Twin-twin transfusion syndrome is a complication unique to monochorionic pregnancy, where shared placental vascular connections can lead to a circulatory imbalance, resulting in preterm delivery and attendant in utero or neonatal mortality. The only disease-modifying treatment is fetoscopic laser ablation of blood vessels, which has attendant risks of invasive intrauterine therapy. OBJECTIVE: In this first-in-human technical feasibility and safety study, we investigated noninvasive, ultrasound-guided high-intensity focused ultrasound to occlude placental vascular targets as identified by color Doppler. The 2 outcomes were (1) safety: number/rate of patients experiencing significant iatrogenic harm, for first 14 days after high-intensity focused ultrasound and (2) efficacy: number/rate of targeted placental vessels which appear occluded at the end of a high-intensity focused ultrasound treatment cycle, assessed using comparison of color Doppler imaging of target anastomoses prehigh-intensity focused ultrasound and posthigh-intensity focused ultrasound exposure. STUDY DESIGN: weeks of gestational age. RESULTS: Ten participants underwent targeted ultrasound-guided high-intensity focused ultrasound occlusion of placental blood vessels that connected the 2 circulations, verified by color Doppler imaging, in whom 27 of 30 (90%) targeted placental vessels were successfully occluded by ultrasound-guided high-intensity focused ultrasound. No treatment-related significant maternal or fetal adverse events were recorded, and 18 of 20 fetuses were alive 14 days post-treatment. Participants expressed positive attitudes toward ultrasound-guided high-intensity focused ultrasound, valuing clear and consistent communication and sufficient time to consider participation in the study. CONCLUSION: In this Phase 1 study, ultrasound-guided high-intensity focused ultrasound showed a high rate of successful occlusion of placental vascular targets and no adverse side effects were observed within 14 days of treatment in women with early-onset twin-twin transfusion. While clinical efficacy of the technique could not be formally evaluated, 5 participants required fetoscopic laser and of the pregnancies treated, 12 of 20 neonates were alive at discharge.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Ultrasound-guided high-intensity focused ultrasound is technically feasible and safe for occluding placental vessels in early-onset twin-twin transfusion syndrome
Date Crossref
01/05/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Assisted Reproductive Technology and Twin PregnancyEctopic Pregnancy Diagnosis and ManagementPreterm Birth and Chorioamnionitis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.