Aller au contenu principal
Accès ouvert déclaré 2026 article

Optimized workflow for pentaspline PFA and its impact on PVI durability: evidence from systematic remapping

2Citations signalées — pas une note de qualité
6Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

AIMS: Real-world series report substantial rates of pulmonary vein (PV) reconnection following index procedure with a pentaspline pulsed-field ablation (P-PFA) catheter. The contrast with initial durability data suggests this may be due to limitations in procedural workflow. METHODS AND RESULTS: We conducted a single-centre, prospective study including consecutive patients undergoing first-time P-PFA pulmonary vein isolation (PVI), subsequently scheduled for systematic invasive remapping ≥30 days after the index procedure. Workflow was progressively refined in three phases, aiming at ensuring adequate tissue contact and based on previous remapping findings. The primary endpoint was PVI durability, per vein and per patient. Of 118 enrolled patients, 94 (Phase 1:n = 30; Phase 2:n = 34; Phase 3:n = 30) underwent systematic remapping, where 13, 10, and 1 reconnected PVs were observed in Phases 1, 2, and 3, respectively. This resulted in per-vein durability of 89.8%, 92.9%, and 99.2% (P = 0.005) and per-patient durability of 60.0%, 76.5%, and 96.7% (P = 0.004). Mean total PFA applications increased from 36.8 ± 5.2 in Phase 1 to 52.1 ± 8.0 and 58.7 ± 15.1 in Phases 2 and 3, respectively (P < 0.001). Median procedure time rose from 43 (39-50) minutes in Phase 1 to 46 (42-56) minutes in Phase 2 and 69 (61-77) minutes in Phase 3 (P < 0.001), with significant parallel increases in LA dwell time (P < 0.001) across phases. No major or minor complications occurred during index or remapping procedures. CONCLUSION: Progressive workflow refinements for pentaspline P-PFA markedly improved PVI durability to nearly 100%, supporting the concept that PV reconnection is predominantly technique-dependent rather than intrinsic to catheter or waveform design.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Optimized workflow for pentaspline PFA and its impact on PVI durability: evidence from systematic remapping
Date Crossref
13/05/2026
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Atrial Fibrillation Management and OutcomesHepatocellular Carcinoma Treatment and PrognosisVenous Thromboembolism Diagnosis and Management

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.