Hematological parameter dynamics in critically ill patients treated with oXiris®-based CRRT and CytoSorb® hemoadsorption: a prospective single-center study
Résumé fourni par la source
Hemoadsorption is increasingly used as adjunctive extracorporeal support in sepsis and septic shock. Comparative data on device-specific hematologic effects remain limited. CytoSorb ® and oXiris ® are among the most widely applied hemoadsorption devices, but their impact on blood element kinetics has not been fully characterized. In a prospective single-center observational study, 66 patients with sepsis or septic shock underwent hemoadsorption combined with continuous renal replacement therapy (CRRT) using either CytoSorb ® ( n = 36) or oXiris ® ( n = 30). Hemoglobin (Hb), hematocrit (Hct), erythrocytes (RBC), and platelets (PLT) were measured prior to and following hemoadsorption. Descriptive analyses and statistical tests were employed to evaluate between-group differences in hematologic parameters. Clinically relevant declines defined as ≥ 15% reduction in Hb, Hct, and RBC, and ≥ 50% in PLT were treated as events in time-to-event (TTE) analysis. CytoSorb ® was associated with significant reductions in Hb, Hct, RBC, and PLT, while no statistically significant hematologic changes were observed with oXiris ® . TTE analyses showed that CytoSorb ® led to faster declines across all parameters in reaching predefined reductions. Median times to predefined thresholds ranged from 19.6 to 27.6 h with CytoSorb ® , compared with 38.9 to 42.1 h with oXiris ® , despite shorter treatment duration in the CytoSorb ® group. CytoSorb ® hemoadsorption results in more pronounced and faster hematologic deterioration compared with oXiris ® , indicating meaningful device-specific differences in blood element kinetics during extracorporeal therapy. Close hematologic monitoring is particularly important when CytoSorb ® is used. Larger multicenter studies with mechanistic biomarkers are needed to validate these findings.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Hematological parameter dynamics in critically ill patients treated with oXiris®-based CRRT and CytoSorb® hemoadsorption: a prospective single-center study
- Date Crossref
- 12/05/2026
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.