Circuit Modeling for In Situ 21 cm Radiometer Calibration
Rattachement africain : Afrique du Sud, gb, ru, it, fr, be, in, mt, nl, de, cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Recent experiments in cosmology, particularly those aimed at detecting the faint, redshifted, global 21[Formula: see text]cm hydrogen line (depth [Formula: see text], [Formula: see text]), have imposed stringent new requirements on radiometer calibration. In this work, we present a framework for circuit modeling and parameter inference to strengthen these calibration pipelines. This new approach enables in situ characterization of otherwise immeasurable systematics using physically motivated models. A combination of frequentist and Bayesian techniques are employed in a pipeline that supports iterative modeling, robust parameter estimation, and detailed uncertainty quantification. The framework is applied to the REACH telescope, where the precise correction of variations in the radio signal paths arising from component aging or environmental effects is critical. Circuit models of REACH’s calibration sources are developed, with the goal of predicting source temperature corrections that are conventionally obtained from laboratory measurements. By fitting the models to measured data using a convolutional cost function, a strong agreement with RMS residuals no worse than [Formula: see text] is obtained. However, Bayesian inference reveals that the resulting temperature corrections can have uncertainties on the order of 1 to [Formula: see text], caused by reflection coefficient degeneracies, measurement noise, and errors in the models. To combat this, posteriors obtained from laboratory measurements are employed as updated priors, reducing correction uncertainties down to [Formula: see text]. Ultimately, the framework provides a means of dynamically accounting for drift in system non-idealities over time, addressing the increasing precision demands of global 21 cm radio astronomy.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- Circuit Modeling for <i>In Situ</i> 21 cm Radiometer Calibration
- Date Crossref
- 01/03/2026
- Éditeur
- World Scientific Pub Co Pte Ltd
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.