ABSTRACT NUMBER: ESOC2026YS275 A COMPARATIVE STUDY OF CT-PERFUSION/MR-DWI MISMATCH IN MEDIUM/DISTAL VESSEL OCCLUSION; ARE PERFUSION MAPS MADE FOR AN LVO-WORLD?
Rattachement africain : ch. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Background and aims Perfusion imaging is routinely used to estimate infarct core and penumbra in patients with large vessel occlusion (LVOs), thus having an important role in reperfusion strategies. Common perfusion-derived threshold-based maps (Tmax, CBF, CBV) have been validated mainly in LVOs and in trials that shaped thrombectomy indications. However, medium/distal vessel occlusions (MDVOs) differ from LVOs in occlusion size, collateral patterns, hemodynamic impact, and often produce smaller, more heterogeneous perfusion abnormalities. These differences lead to the hypothesis of reduced accuracy of standard perfusion thresholds and automated software outputs when used to predict final infarct in MDVOs . We investigated the effectiveness of LVO-perfusion-derived maps in prediction of final infarct in MDVO. Methods This retrospective single center observational cohort study included 71 MDVO-patients. Patients were stratified into fully recanalized (>TICI2b ) and non-recanalized ( 4 s , Tmax>6 s, cerebral blood flow (CBF), and cerebral blood volume (CBV). Final infarct was manually segmented on diffusionweighted MRI performed ~24h postpresentation. Perfusion–DWI spatial correspondence and volumetric agreement were assessed with different metrics (Absolute and relative volume difference, Dice score, Hausdorff-distance and distance between the centers of mass). We exploratively analyzed the data and correlated them with anatomical (occlusion-site, vessel-size) and clinical parameters (NIHSS, mRS). Results Currently we are at the result-interpretation-phase. Our early results suggest that the infarct-core is poorly represented by perfusion maps. Conflict of interest No disclosures for the authors regarding the carrying-out of the project, no specific funding sources were required for this project
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- ABSTRACT NUMBER: ESOC2026YS275 A COMPARATIVE STUDY OF CT-PERFUSION/MR-DWI MISMATCH IN MEDIUM/DISTAL VESSEL OCCLUSION; ARE PERFUSION MAPS MADE FOR AN LVO-WORLD?
- Date Crossref
- 01/05/2026
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.