Aller au contenu principal
Accès ouvert déclaré 2026 conference-abstract

ABSTRACT NUMBER: ESOC2026A1381 AUTOMATED WHITE MATTER HYPERINTENSITY SEGMENTATION: THRESHOLDED BIANCA VS TRUE-NET

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background and aims White matter hyperintensities (WMH) as part of the small vessel disease score are increasingly subjected to automated WMH segmentation to enhance objectivity and comparability across studies. In this study, we investigated whether a deep-learning based automated segmentation model, TrUE-Net performs better than 0.85 thresholded BIANCA (Brain Intensity AbNormality Classification Algorithm), a k-nearest neighbour approach in identifying WMH lesions Methods We compared the robustness and performance of BIANCA_0.85 vs. TrUE-Net using data of the prospective Berlin Long-term Observation of Vascular Events=BeLOVE, () cohort and the WMH Segmentation Challenge dataset () using manually delineated WMH masks as ground truth. We assessed the overall performance, precision, sensitivity using three datasets. One consisting of a mixed dataset (n=109), data from the BeLOVE cohort (n=59) with mixed vascular lesions, examined at a 3T Siemens and 3 T Philips scanner and data from the Challenge dataset (n=50) with a variety of MRI scanners, comparing their DICE score (DC) and accounting for factors such as lesion volumes Results TrUE-Net showed better performance, precision, sensitivity in all 3 datasets (DC: 0.66±0.19/0.64±0.22/0.69±0.15) than BIANCA_0.85 (DC: 0.5±0.22/ 0.57±0.24/0.41±0.14) (figure1) and greater robustness towards different scanner types than BIANCA _0.85 (figure2). Out of the investigated factors (figure3), lesion volume differences had the most impact on the performance of TrUE-Net Conclusions TrUE-Net proves to be more accurate and robust in segmenting WMH than BIANCA_0.85, even with different MRI scanners, making it more reliable for analysing large amounts of data, both cross-sectional and longitudinal. Conflict of interest nothing to disclose regarding the topic of the submitted abstract: Chiara-Sophia Hübotter, Uchralt Temuulen, Joachim E. Weber, Katharina Schönrath, Ira Rohrpasser-Napierkowski, Tuncer, Mehmet, Matthias Endres, Ivana Galinovic, Kersten Villringer Figure 1 - belongs to Results Figure 2 - belongs to Results Figure 3 - belongs to Results

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
ABSTRACT NUMBER: ESOC2026A1381 AUTOMATED WHITE MATTER HYPERINTENSITY SEGMENTATION: THRESHOLDED BIANCA VS TRUE-NET
Date Crossref
01/05/2026
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Acute Ischemic Stroke ManagementDementia and Cognitive Impairment ResearchFunctional Brain Connectivity Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.