Aller au contenu principal
Accès ouvert déclaré 2026 article

Multi‐Frequency Electrocochleography Results in Fewer Drop Alarms During Cochlear Implant Insertion

0Citations signalées, ce qui n’est pas une note de qualité
21Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVE: To evaluate intracochlear electrocochleography (ECochG) amplitude parameters during cochlear implantation (CI) using a novel multi-frequency ECochG algorithm. METHODS: A multi-institutional, prospective cohort study was performed at 18 high-volume CI centers. The inclusion criteria were adults with sensorineural hearing loss and audiometric thresholds of ≤ 90 dB hearing level at 500 Hz undergoing CI with Advanced Bionics (Valencia, CA) Ultra 3D devices between 2024 and 2025. ECochG recordings were performed with simultaneous multi-frequency stimulation of four frequencies between 125 and 4000 Hz during cochlear implant insertion. Concurrent multi-frequency recording allowed extraction of amplitude and phase of each frequency individually. Post hoc analysis was performed to determine the difference in the number of drop alarms between single- and multi-frequency ECochG. An ECochG amplitude drop of 6 dB was defined as a drop alarm. Insertion track patterns were compared between single- and multi-frequency ECochG. RESULTS: One hundred ninety-five ears were included. Mean number of drop alarms for the single-frequency algorithm was 1.72 (95% CI: 1.52, 1.92; median 1) compared to 0.42 (95% CI: 0.31, 0.53; median 0) for multi-frequency; p < 0.001. The number of Type C patterns (rise in amplitude during insertion followed by a drop) decreased with the multi-frequency ECochG algorithm compared to the single-frequency ECochG algorithm. The number of Type D patterns (no-response) decreased, indicating that multi-frequency ECochG generated more responses across the cochlea than single-frequency ECochG. CONCLUSIONS: A novel multi-frequency ECochG algorithm during CI is associated with fewer drop alarms and altered insertion track patterns, which may provide a more accurate assessment of the cochlear microenvironment.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Multi‐Frequency Electrocochleography Results in Fewer Drop Alarms During Cochlear Implant Insertion
Date Crossref
05/05/2026
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Hearing Loss and RehabilitationHearing, Cochlea, Tinnitus, GeneticsEar Surgery and Otitis Media

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.