Aller au contenu principal
Accès ouvert déclaré 2026 article

Value of blood pressure for detecting serious illness in children attending acute care settings in low- and middle-income countries: a multicentre observational study

0Citations signalées — pas une note de qualité
13Institutions déclarées
7Pays d’affiliation déclarés

Résumé fourni par la source

Background In children, the value of routine blood pressure measurement in first assessment at the emergency department has been questioned. This has, however, not yet been evaluated in low- and middle-income countries (LMICs) where the incidence of serious illness is high. This study assessed the predictive value of low systolic blood pressure to detect serious illness in children attending acute care settings in LMICs. Methods This observational study is based on data from children attending three acute care settings in The Gambia and Suriname. Hypotension was defined by age-adjusted reference values according to Advanced Paediatric Life Support (APLS) and Paediatric Advanced Life Support (PALS) cut-offs. The outcome measure was a composite marker of serious illness consisting of admission or referral to a higher level of care. A logistic regression analysis was used to evaluate the association between hypotension and serious illness for each setting separately. Results 20 185 visits from Gambia rural, 398 visits from Gambia urban and 1817 visits from Suriname were included. Hypotension was present in 8.3–17.3% of visits and serious illness in 3.9–15.7%. Hypotension was not significantly associated with serious illness in Gambia urban (OR APLS 3.2 (0.7–10.9) and OR PALS 1.4 (0.1–7.6)) and Suriname (OR APLS 1.3 (0.9–1.9) and OR PALS 1.7 (0.9–3.2)), and with an inverse association in Gambia rural (OR APLS 0.6 (0.5–0.7) and OR PALS 0.9 (0.5–1.4)). Conclusions Our results do not show a significant association between hypotension and serious illness in LMICs. Our results suggest that routine blood pressure measurement does not aid in the evaluation of well-appearing children attending acute care settings in LMICs.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Value of blood pressure for detecting serious illness in children attending acute care settings in low- and middle-income countries: a multicentre observational study
Date Crossref
04/05/2026
Éditeur
BMJ
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Global Maternal and Child HealthSepsis Diagnosis and TreatmentTrauma and Emergency Care Studies

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.