Aller au contenu principal
2026 article

From H p(10) to H p: impact of implementing ICRU/ICRP report 95 personal dose quantity on CaSO4:Dy-based TLD dosemeters – a Monte Carlo study

0Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

The International Commission on Radiation Units and Measurements (ICRU), in collaboration with the International Commission on Radiological Protection (ICRP), has introduced new operational quantities in ICRU Report 95. Among these, the personal dose Hp addresses the significant limitations of the currently used Hp (10), which can overestimate the effective dose by up to a factor of 5.5 at photon energies below 70 keV. These changes necessitate a re-estimation of dosemeter response to evaluate potential modifications in dose algorithms and detector design. In this study, the performance of CaSO4:Dy thermoluminescent dosemeter (TLD) badges was investigated for the new operational quantity Hp and compared with the existing Hp (10). The badge response was simulated over photon energy range 12.3-1250 keV using the Monte Carlo Simulation code FLUKA and benchmarked against experimental validation. To correct for energy-dependent overestimation at lower photon energies, a new dose evaluation algorithm for Hp was developed based on disc dose ratio (R12). The disc dose ratio (R12) refers to the ratio of absorbed doses measured in CaSO₄:Dy TL discs D1 and D2 positioned under different filtration conditions within the badge and serves as an energy-sensitive parameter for correcting the over-response of the dosemeter in terms of Hp. The proposed algorithm demonstrated strong compliance with IEC 62387:2020 performance criteria (acceptance range 0.71-1.67), with 95% of estimated Hp values lying within 0.9-1.3 of the delivered dose. These results confirm that CaSO4:Dy TLD badges, when combined with the improved algorithm, are fully compatible with the new operational quantities recommended in ICRU Report 95, ensuring reliable application in personnel dosimetry.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
From <i>H</i> p(10) to <i>H</i> p: impact of implementing ICRU/ICRP report 95 personal dose quantity on CaSO4:Dy-based TLD dosemeters – a Monte Carlo study
Date Crossref
30/04/2026
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Radiation Dose and ImagingAdvanced Radiotherapy TechniquesEffects of Radiation Exposure

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.