Variability in Tissue Interface Temperature During Pulse Field Atrial Ablation: Implications for Real-Time Contact Assessment
Résumé fourni par la source
BACKGROUND: Pulsed field ablation (PFA) can generate low-intensity catheter-tissue interface heating. Recently, a large-focal PFA catheter able to measure the tip-tissue interface temperature has become available. Accordingly, we aimed to characterize the electrode tip-tissue interface temperature dynamics during PFA. METHODS: A retrospective single-center study evaluated PFA lesions in 41 consecutive patients undergoing atrial fibrillation ablation using the lattice-tip catheter. Lesions were grouped by anatomic location with interface temperatures measured via catheter tip thermocouples. The association of predictors with lesion temperatures was evaluated with a mixed-effects model. An analysis of lesion dimensions and interface temperatures was also performed in swine. RESULTS: Among 41 patients, 2779 pulse field lesions were analyzed. Mean peak temperature was 41.7±2.2 °C (range, 37.2 °C–52.8 °C) and average temperature was 39.5±1.4 °C (range, 36.4 °C–46.9 °C). Temperatures exceeded 50 °C in 10 of 2779 (0.4%) lesions, most often in the anterosuperior left superior pulmonary vein (5/10). Univariate analysis showed peak temperature was positively associated with previous lesion temperature ( r =0.65 [95% CI, 0.63–0.67]; P <0.001) and had weak associations with time between lesions ( r =−0.15 [−0.19 to −0.11]; P <0.001) and percentage impedance drop ( r =0.20 [95% CI, 0.16–0.23]; P <0.001). Even after multivariable analysis, the peak temperature remained significantly lowest at the right carina (39.7 °C), anterosuperior right superior pulmonary vein (40.9 °C), and right superior pulmonary vein roof (40.5 °C) locations. Swine demonstrated a moderately strong association between lesion depth with peak temperature ( R =0.53 [95% CI, 0.20–0.75]; P =0.003) and average temperature ( R =0.49 [95% CI, 0.16–0.73]; P =0.007). CONCLUSIONS: Lattice-tip temperatures during PFA vary substantially, with right superior pulmonary vein sites often demonstrating a blunted temperature response compared with other sites. Peak and average temperatures correlated with lesion depth.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Variability in Tissue Interface Temperature During Pulse Field Atrial Ablation: Implications for Real-Time Contact Assessment
- Date Crossref
- 01/05/2026
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.