Aller au contenu principal
2026 article

Impact of TAVR Failure Mechanism on Outcomes After Reintervention: From the EXPLANTORREDO-TAVR Registry

3Citations signalées — pas une note de qualité
44Institutions déclarées
9Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: As transcatheter aortic valve replacement (TAVR) expands to patients with longer life expectancy, the impact of failure mechanisms on outcomes of TAVR-explant and redo-TAVR remains uncertain. We sought to evaluate outcomes of TAVR reintervention based on the failure mechanism of the index transcatheter aortic valve. METHODS: From 2009 to 2022, 553 patients from 29 centers in the EXPLANTORREDO-TAVR registry (Explant or Redo Transcatheter Aortic Valve Replacement) underwent TAVR-explant or redo-TAVR for transcatheter aortic valve failure. Patients with endocarditis were excluded. Patients with structural valve deterioration (SVD, N=224 [64.9%]) were compared with those with nonstructural valve dysfunction (NSVD, N=121 [35.1%]), comprising paravalvular leak (86.0%) and prosthesis-patient mismatch (14.0%). Outcomes were assessed at 30 days and 1 year. RESULTS: Mean age was 75.6±9.3 years, with 42% women. There were no differences in reintervention type between groups (redo-TAVR in 58.0% SVD versus 49.6% NSVD; TAVR-explant: 42.0% versus 50.4%; P =0.14). Compared with NSVD, SVD was the predominant mode of failure in balloon-expandable valves (50.7% versus 24.8%; P <0.001), had a longer time to reintervention (50.7 versus 5.5 months; P <0.001), and favored non–balloon-expandable valves at redo-TAVR (56.9% versus 33.3%; P =0.003). Mortality at 30 days and 1 year did not differ significantly between SVD and NSVD for either redo-TAVR (30 days: 3.2% versus 1.7%, P =1.00; 1 year: 18.0% versus 12.0%; P =0.47) or TAVR-explant (30 days: 16.3% versus 12.1%, P =0.63; 1 year: 40.0% versus 29.5%; P =0.39). There were also no differences in risk-adjusted 3-year cumulative mortality between groups (redo-TAVR: hazard ratio, 1.30 [95% CI, 0.68–2.46], P =0.43 [ref=NSVD]; TAVR-explant: hazard ratio, 1.24 [95% CI, 0.64–2.41]; P =0.53). CONCLUSIONS: SVD and NSVD failures had distinct valve types and reintervention timing, with SVD having a longer time to TAVR reintervention, but the failure mechanism did not impact reintervention type or clinical outcomes.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Impact of TAVR Failure Mechanism on Outcomes After Reintervention: From the EXPLANTORREDO-TAVR Registry
Date Crossref
01/06/2026
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiac Valve Diseases and TreatmentsCongenital Heart Disease StudiesMechanical Circulatory Support Devices

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.