Aller au contenu principal
Accès ouvert déclaré 2026 other

Impact of deep learning image reconstruction on ADC quantification and histogram metrics: a phantom study

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Objective Recently, deep learning (DL)-based reconstruction methods have been introduced into clinical magnetic resonance imaging (MRI) systems to enhance image quality and reduce acquisition time. However, their effects on apparent diffusion coefficient (ADC) maps remain unclear. We investigated whether DL-based image reconstruction influences ADC quantification and histogram-based ADC metrics using a calibrated diffusion-weighted imaging (DWI) phantom. Materials and methods A phantom containing vials with known ADC values was scanned on a 3-T system using full (fFOV) and reduced (rFOV) field-of-view DWI sequences. Each acquisition was performed using conventional (DL-OFF) and three DL-based strength levels (low, medium, high). Median ADC values were analyzed for repeatability (coefficient of variation (CV)) and accuracy. Histogram changes and first-order radiomic features were assessed using the Wasserstein distance, Friedman, and Wilcoxon tests. Results ADC estimates showed high repeatability (CV 0.1–1.2%) and good accuracy (deviation -2 to 7%) across all DL levels and sequences. DL reconstruction progressively reduced histogram dispersion, particularly in high-ADC vials. Wasserstein distances increased with DL strength, confirming a progressive effect on ADC value distributions, while median ADC values remained unchanged. Entropy and interquartile range decreased significantly (p < 0.001), whereas kurtosis and skewness increased, with differences showing less stable and sequence-dependent statistical significance. Conclusion DL-based reconstruction maintained accurate and repeatable ADC quantification while reducing the dispersion of ADC values. The effect was more evident for high-ADC regions and the rFOV sequence, resulting in narrower distributions of ADC values. Further investigations comparing different DL-based solutions are warranted to assess the generalizability of these findings in clinical settings. Relevance statement Over the past decade, ADC histogram analysis has proven valuable for quantifying tumor heterogeneity, differentiating tumor grade, and evaluating early treatment response. Deep learning reconstruction narrows ADC distributions and reduces dispersion, supporting its potential in oncologic DWI, while highlighting the need for patient-based validation studies. Key Points DL reconstruction preserved ADC accuracy in both full FOV and reduced FOV DWI. ADC repeatability remained high across DL levels for both DWI sequences. Histogram dispersion progressively reduced across DL levels, particularly in high-ADC vials. Entropy and interquartile ranges decreased progressively with increasing DL strength. Graphical Abstract

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.