Indoor Air Filtration System Performance: Evidence from a Two-Week Office Study Within the EDIAQI Project
Résumé fourni par la source
This two-week pilot study within the Horizon Europe EDIAQI project evaluated the real-life performance of portable air filtration units in two office environments (a small office and a shared kitchen) under continuous device operation and daily filter replacement. Indoor particle concentrations were monitored continuously using low-cost sensors (LCS) from three providers and supported by gravimetric measurements, while daily activity logs documented occupancy patterns, printing, cooking, and other source events together with purifier ON/OFF status. Particulate matter (PM) mass concentrations showed no systematic improvement during purifier ON periods; instead, temporal variability was dominated by indoor activities and episodic emissions, with occasional short-term peaks around filter replacement suggestive of minor resuspension. Chemical analysis provided a clearer picture: polycyclic aromatic hydrocarbons (PAHs) responded differently across fractions and compositions. Across monitored locations, high-molecular-weight PAHs in the PM1 fraction decreased during purifier ON periods (approximately 30% lower on average), whereas low-molecular-weight PAHs measured in total suspended particles (TSP) were higher during ON periods, indicating that semi-volatile fractions and activity/ventilation dynamics can outweigh simple filtration effects. Overall, the findings highlight a gap between laboratory-derived filtration performance metrics and outcomes in occupied, mixed-source indoor environments and emphasise the importance of device sizing, placement, airflow mixing, and complementary source control and ventilation strategies when deploying filtration-based IAQ interventions.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Indoor Air Filtration System Performance: Evidence from a Two-Week Office Study Within the EDIAQI Project
- Date Crossref
- 14/04/2026
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.