Ventricular activation and repolarization in response to physiological and conventional pacing using ultra-high-frequency electrocardiography

0Citations signalées, ce qui n’est pas une note de qualité
9Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : es, cz, nl. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Physiological pacing targeting the cardiac conduction system is increasingly being adopted as an alternative to conventional right ventricular (RV) pacing for the treatment of bradyarrhythmias, although its effects on ventricular repolarization remain underexplored. OBJECTIVE: This study evaluates depolarization and repolarization responses to different pacing techniques using ultra-high-frequency electrocardiograms (UHF-ECGs). METHODS: Temporary pacing was performed at different cardiac areas in 178 patients with bradycardia. Depolarization was assessed via QRS duration (QRSd), QRS area (QRSa), ventricular dyssynchrony (e-DYS), and activation time dispersion (dAT computed from leads V1-V6 and dAT4-6 from leads V1-V6). Repolarization was analyzed using the corrected QT interval (QTc), T-wave area (Ta), Periodic Repolarization Dynamics (PRD), and repolarization time dispersion (dRTc and dRTc4-6). RESULTS: His bundle pacing (HBP) preserved ventricular activation patterns similar to spontaneous rhythm. Left bundle branch pacing (LBBP) induced moderate depolarization changes, primarily due to delayed right ventricular activation, while maintaining left ventricular synchrony. In particular, dAT showed no significant differences between HBP and spontaneous rhythm, while differences between LBBAP and spontaneous rhythm were significant but below 7 ms in median. When restricted to the left ventricle (LV), no significant differences in dAT4-6 were found between LBBAP and spontaneous rhythm. Importantly, e-DYS for HBP showed similar values to spontaneous rhythm, LBBP led to a significant reduction (median differences approximately 20 ms), and RVP was associated with a significant increase (above 15 ms in median). In line with these results, QRSd and QRSa showed the largest values for RVP. In terms of ventricular repolarization, median differences in the QTc interval between pacing modes and spontaneous rhythm were below 3 ms for HBP, above 1 ms for LBBP, and above 20 ms for RVP. All pacing modes led to a reduction in PRD, with the most marked reductions observed for LBBP, particularly for selective LBBP, with median changes with respect to spontaneous rhythm of 4.6 degrees. RT and RTc showed similar trends for all pacing techniques. Ta, however, showed median differences with respect to spontaneous rhythm above 100 and 34 [Formula: see text] Vs when pacing the RV at the apex and the septum, respectively, whereas such median differences were below 16 [Formula: see text] Vs for HBP and below 2 [Formula: see text] Vs for LBBP. CONCLUSION: Physiological stimulation via HBP or LBBAP generates ventricular depolarization and repolarization responses that more closely resembles that of spontaneous rhythm, in high contrast to the largely different response induced by RV pacing. HBP and LBBAP have distinct technical characteristics, including differences in capture thresholds, lead stability, and procedural aspects. These techniques serve as alternatives to conventional RV pacing.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Ventricular activation and repolarization in response to physiological and conventional pacing using ultra-high-frequency electrocardiography
Date Crossref
13/04/2026
Éditeur
Public Library of Science (PLoS)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac electrophysiology and arrhythmiasECG Monitoring and AnalysisCardiac pacing and defibrillation studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.