Aller au contenu principal
Accès ouvert déclaré 2025 article

Ultrasound-Guided In-Plane Subclavian Vein Puncture versus Prior Ultrasound and Landmark Technique: A Randomized Controlled Trial

1Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : de, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Central venous catheterization (CVC) of the subclavian vein is a standard procedure in medicine. Ultrasound guidance is increasingly recommended to improve the success rates and reduce complications. This study compared the success rates and complications of ultrasound-guided microconvex in-plane subclavian puncture (MISP) with those of the landmark technique. METHODS: In this randomized controlled trial, 101 patients scheduled for elective surgery were enrolled and randomly assigned to either the group MISP or the control group using the landmark technique after ultrasound prescan. The primary end point was an a priori defined composite risk score including puncture attempts, required time, posterior venous wall injury, arterial punctures, hematoma formation, hemo-, pneumothorax, and catheter mispositioning. The secondary and exploratory end points included success rates, complication rates, and procedural times. Comparisons between groups were performed using Student t test, χ2 test, and Mann-Whitney U test with a significance level of 0.05. Data are mean ± standard deviation [SD], frequencies (%) or 95% confidence interval [CI] [lower limit-upper limit]). RESULTS: The mean ± SD composite risk score was significantly lower in the MISP group compared to control (6.4 ± 5.9 vs 11.6 ± 10.8; mean diff 5.21 [95% CI, 1.71-8.71], P = .028). The MISP technique demonstrated significantly higher as-treated overall success rates (86% [95% CI, 74.6%-93.9%] vs 71% [95% CI, 56.2%-82.5%], P = .046) and significantly reduced the risk of arterial punctures (1.9% [95% CI, 0.05%-10.45%] vs 12% [4.5%-24.3%], number needed to harm: 10 punctures, P = .047). One pneumothorax was noted in both groups (2% each). The mean procedural time was 5 minutes longer in the MISP group (P < .001). CONCLUSIONS: Compared with the landmark technique, the ultrasound-guided MISP technique significantly reduced the risk of complications. The extended procedural time may be justified by lower complication rates. Further studies should evaluate the implementation of the MISP technique as a standard approach for subclavian vein catheterization.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Ultrasound-Guided In-Plane Subclavian Vein Puncture versus Prior Ultrasound and Landmark Technique: A Randomized Controlled Trial
Date Crossref
25/11/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Central Venous Catheters and HemodialysisDiagnosis and Treatment of Venous DiseasesVenous Thromboembolism Diagnosis and Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.