Modality-agnostic, patient-specific digital twins modeling temporally varying digestive motion

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Objective. Clinical implementation of deformable image registration (DIR) requires voxel-based spatial accuracy metrics such as manually identified landmarks, which are challenging to implement for highly mobile gastrointestinal (GI) organs. To address this, patient-specific digital twins (DTs) modeling temporally varying motion were created to assess the accuracy of DIR methods.Approach. A total of 21 motion phases simulating digestive GI motion as 4D image sequences were generated from static 3D patient scans using published analytical GI motion models through a multi-step semi-automated pipeline. Eleven datasets, including six T2-weighted FSE MRI (T2w MRI), two T1-weighted 4D golden-angle stack-of-stars, and three contrast-enhanced computed tomography scans were analyzed. The motion amplitudes of the DTs were assessed against real patient stomach motion amplitudes extracted from independent 4D MRI datasets using hierarchical motion reconstruction. The patient-specific DTs were then used to assess six different DIR methods using target registration error, Dice similarity coefficient (DSC), and the 95th percentile Hausdorff distance using summary metrics and voxel-level granular visualizations. Finally, for a subset of T2w MRI scans collected from patients treated with magnetic resonance-guided radiation therapy, dose distributions were warped and accumulated to assess dose warping errors (DWEs), including evaluations of DIR performance in both low- and high-dose regions for patient-specific error estimation.Main results. Our proposed pipeline synthesized patient-specific DTs modeling realistic GI motion, achieving mean and maximum motion amplitudes and a mean log Jacobian determinant within 0.8 mm and 0.01, respectively, similar to published real-patient gastric motion data. It also enables the extraction of detailed quantitative DIR performance metrics and supports rigorous validation of dose mapping accuracy prior to clinical implementation.Significance. The developed pipeline enables rigorously testing DIR tools for dynamic, anatomically complex regions facilitating granular spatial and dosimetric accuracies.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

Aucun DOI disponible pour le contrôle Crossref.

Les sujets associés

Advanced Radiotherapy TechniquesMedical Imaging Techniques and ApplicationsAugmented Reality Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.