Aller au contenu principal
Accès ouvert déclaré 2026 article

Comparative 30-day Echocardiographic Outcomes of Myval versus Sapien and Evolut THVs: Insights from LANDMARK Trial

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Aims Several factors, including device design, annulus size, and sizing strategies, influence transcatheter heart valve (THV) haemodynamic outcomes in patients with aortic stenosis (AS). This sub-study evaluates early (30-day) echocardiographic outcomes of the Myval, Sapien, and Evolut THV series, focusing on haemodynamic performance and valve durability. Methods and results The LANDMARK trial is a prospective, randomised, multicentre, open-label, non-inferiority trial comparing 384 patients implanted with Myval THV series to 384 receiving Sapien and Evolut THV series. Haemodynamic assessments followed Valve Academic Research Consortium-3 recommendations. At 30-day, haemodynamic device success rates were 85.9%, 77.8, and 85.4% for Myval, Sapien, and Evolut THV series, respectively (PMyval-Sapien = 0.03 and PMyval-Evolut = 0.98). Significant improvements in peak aortic flow velocity, pressure gradients, effective orifice area (EOA), Doppler velocity index (DVI), and cardiac indices were observed across all groups, except for unchanged left ventricular ejection fraction. Moderate prosthesis-patient mismatch (PPM) was less frequent with Myval THV series(11.3%) vs. Sapien THV series(21.8%), but higher than Evolut THV series (5.3%) (PMyval-Sapien = 0.0024, PMyval-Evolut = 0.0396), while severe PPM showed no significant differences (4.2% vs. 6.3% vs. 1.8%; PMyval-Sapien = 0.394, PMyval-Evolut = 0.2438). Rates of ≥ moderate paravalvular leak (PVL) were lower in Myval (3.5%), and Sapien (1.7%) compared with Evolut THV series (8.3%) (PMyval-Sapien = 0.3769, PMyval-Evolut = 0.0336). Myval THV series required minimal oversizing compared with Evolut THV series (P < 0.0001). Conclusion The Myval THV series demonstrates short-term haemodynamic performance comparable to Evolut THV series and superior to Sapien THV series. Including intermediate sizes minimizes oversizing, underscoring its potential as an alternative for TAVI patients. Long-term follow-up is necessary to confirm these findings.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

Aucun DOI disponible pour le contrôle Crossref.

Les sujets associés

Cardiac Valve Diseases and TreatmentsCardiovascular Function and Risk FactorsCongenital Heart Disease Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.