Paving the way for automated transscleral cyclophotocoagulation: predicting ciliary body arc length from biometric data using a two-sphere eye model
Rattachement africain : hu. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Purpose To improve determination of the treatment area for the personalization of subliminal transscleral cyclophotocoagulation (SL-TSCPC) procedures in glaucoma treatment, we designed a biometry based model of the human eye to find the estimated cilary body (CB) arc length (ECBAL) and the calculated CB distance (CCBD). Methods We developed a rotationally symmetric modified two-sphere eye model based on axial length (AL), mean keratometry (mean K), anterior chamber depth (ACD), lens thickness (LT), and white-to-white (WTW). ECBAL and CCBD were calculated for each eye. Fluence was calculated with standardized parameters. Results Publicly accessible biometric measurements for 24,001 eyes were pooled for analysis. The mean ECBAL was 23.99±1.8 mm. The correlations of ECBAL with AL and ACD were 0.723 and 0.754 respectively (p < 0.01). The number of eyes with an ECBAL 21.7–22.0 mm was 131 of 24,001 (0.55%). The mean CCBD was 4.21±0.8 mm. The number of eyes with a CCBD of 3.8 mm was 1,445 of 24,001 (6.02%). Mean fluence was 120.33±9.0 J/cm2. A mean difference of −8.18 ± 6.9%, ranging from −22.66% to +29.07% in fluence was observed with treating only the recommended 22 mm versus the ECBAL. Conclusions This study demonstrated that use of 22.0 mm as the standard treatment arc length may under or overdose laser treatment in many eyes. Precise estimation or exact localization of the CB treatment area is required to accurately calculate fluence. Translational Relevance The model proves that CB arc length is a variable while current guidelines consider it a constant
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Paving the way for automated transscleral cyclophotocoagulation: predicting ciliary body arc length from biometric data using a two-sphere eye model
- Date Crossref
- 31/03/2026
- Éditeur
- openRxiv
- Type
- posted-content
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of Szeged Department of Ophthalmology pays non établi dans la noticeUniversité ou école supérieure
Department of Ophthalmology — University of Szeged.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.