Aller au contenu principal
Accès ouvert déclaré 2026 article

The positioning of pedicle screws in the first instrumented lumbar vertebra influences the reoperation rate due to the development of adjacent segment disease

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : ar, br. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

INTRODUCTION: Adjacent Segment Disease (ASD) is a significant concern following lumbar arthrodesis, particularly in patients aged 55 and older. While various risk factors for ASD have been investigated, modifiable surgical factors related to pedicle screw (PS) positioning remain underexplored. OBJECTIVES: This study aims to specifically evaluate the correlation between PS positioning and reoperation rates due to ASD in elderly patients undergoing lumbar arthrodesis, identifying specific surgical parameters that could mitigate the risk of ASD. METHODS: We conducted a retrospective analysis of 48 patients aged 55 and older who underwent posterior lumbar arthrodesis from May 2013 to May 2021. Patients had 2 to 4 segments fused between L2 and S1 and a minimum follow-up of 2 years. We assessed PS positioning parameters, including the angle between the first PS and the upper vertebral endplate (VE) and the PS tip-VE distance, using logistic regression to analyze associations with reoperation rates. ROC curve analysis was performed to identify optimal cut-off points. RESULTS: Out of the 48 patients, 7 (14.6%) required reoperations for ASD, with an average follow-up of 6.5 years. A greater PS tip-VE distance was significantly associated with a lower probability of reoperation (OR: 0.68; p = 0.001), while a higher PS-VE angle correlated with an increased risk (OR: 1.48; p = 0.001). Critical cut-off values identified included a PS tip-VE distance of ≥ 7.5% (sensitivity: 90.63%) and a PS-VE angle of ≥ 10° (sensitivity: 75.00%). CONCLUSIONS: Our findings indicate that optimizing pedicle screw positioning-specifically maintaining a PS tip-VE distance of at least 7.5% and a PS-VE angle below 10°-can significantly reduce reoperation rates due to ASD in patients over 55. Implementing these specific parameters in surgical practice may lead to improved patient outcomes and reduced incidence of ASD-related interventions.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
The positioning of pedicle screws in the first instrumented lumbar vertebra influences the reoperation rate due to the development of adjacent segment disease
Date Crossref
03/03/2026
Éditeur
Universidad Nacional de Córdoba
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Spinal Fractures and Fixation TechniquesScoliosis diagnosis and treatmentIntraoperative Neuromonitoring and Anesthetic Effects

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.