Le résumé fourni par la source

Title of Dataset 2025_JINST_20_P12015 ROBUK Dataset Numerical data for the following article: Title Tests of charge sharing compensation algorithm implemented in a single pixel counting integrated circuit operating with Si and CdTe pixel detectors / M. ŻOŁĄDŹ, P. OTFINOWSKI, P. GRYBOŚ, R. KŁECZEK, G. DEPTUCH Journal of Instrumentation; ISSN 1748-0221 — 2025 — vol. 20, no. 12, art. no. P12015, pp. [1], 1–9. Authors M. Zoladz P. Otfinowski P. Grybos R. Kleczek G. Deptuch Affiliation AGH University of Science and Technology, Kraków, Poland Methodology Figures 4–12 contain the measurement data of integrated circuits. Dataset Contents The set contains the data for the following figures: Figure 4. Measurements done with 0.75 mm thick CdTe detector module illuminated by fluorescence X-rays from Ag and Mo targets. (a) Distribution of counts across the pixel matrix. The measured integral spectra from the selected pixels were summed. (b) Integral spectra acquired with charge sharing compensation. Figure 6. Integral spectra of X-rays from monochromatic radioactive sources for charge sharing compensation disabled and enabled: (a) Am-241 (59.54 keV), (b) Cd-109 (88.03 keV and 25 keV). Figure 7. Integrated threshold scans of radiation from 60 kVp and 130 kVp X-ray tube with charge sharing compensation disabled and enabled. Figure 8. Integral spectra acquired with signal summing disabled (a) and enabled (b). (c) Signal amplitude distribution comparison. Figure 9. Results of measurements with signal summing enabled and MPR algorithm: (a) SRHs spectra, (b) amplitude distribution, (c) registered counts, (d) counts distribution. Figure 10. Results similar to Fig. 9 for discrimination level equal to 585. Figure 11. Count rate and pulse amplitudes vs. laser pulse frequency measured without charge sharing compensation: (a) spectra, (b) performance vs frequency. Figure 12. Count rate and pulse amplitudes vs. laser pulse frequency measured with charge sharing compensation: (a) number of counts, (b) performance vs frequency. Data Format Data in .xlsx file with description in each column. File Structure Main folder: raw_data (ZIP file) Data files in the folder: Figure_4 Figure_6a Figure_6b Figure_7 Figure_8 Figure_9 Figure_10 Figure_11 Figure_12 Acknowledgements This research is funded by the National Science Center, Poland, project no. 2023/51/B/ST7/01782.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.