Improved Methods for Recording Accurate Collision Cross Sections Using Cyclic Ion Mobility-Mass Spectrometry

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Traveling wave ion mobility (TWIM) is a gas-phase separation technique widely used in structural biology to rapidly probe protein conformational states, and in complex mixture analysis to catalyze an array of chemical measurements. Analyte size information can be extracted from TWIM data as collision cross section (CCS) values, which are physicochemical descriptors of the analytes. However, calibration using ions of known CCS is currently required. Recently, an improved TWIM calibration approach was introduced which incorporates blend and radial expressions derived from velocity relaxation and axial confinement effects. This approach offers several benefits over conventional power-law calibrations, including accurate calibration over a wide range of separation conditions and analyte classes using a universal calibrant set. While the blend and radial calibrations were extensively validated using a linear TWIM separator, next-generation cyclic ion mobility (cIM) offers additional benefits, such as scalable resolution using multi-pass separations and the ability to subject ions to multiple stages of activation and separation (i.e., IMSn). The original work provided a brief application of the blend and radial expressions to cIM calibrations, but these cIM CCS calibrations were only applied to a basic single-pass mode of operation under limited separation conditions. Here, we describe a comprehensive method for accurate cIM calibrations using the blend and radial expressions. Correcting ion arrival times for the time spent outside the separator and using conditions that minimize velocity relaxation effects lowered CCS measurement error. We also provide an optimized workflow for calibration using the blend and radial expressions in multi-pass and IMSn modes of operation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Improved Methods for Recording Accurate Collision Cross Sections Using Cyclic Ion Mobility-Mass Spectrometry
Date Crossref
27/03/2026
Éditeur
American Chemical Society (ACS)
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Mass Spectrometry Techniques and ApplicationsAdvanced Proteomics Techniques and ApplicationsMetabolomics and Mass Spectrometry Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.