Aller au contenu principal
Accès ouvert déclaré 2026 article

Multi-task transformer framework and radiomic signatures for multi-lesion segmentation, detection, and grading in diabetic retinopathy

0Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

• A transformer-enabled multi-task pipeline was developed for integrated DR lesion segmentation, detection, and severity grading across multi-center datasets. • Transformer-based models (SegFormer, Deformable DETR) consistently outperformed CNN architectures for multi-lesion localization with strong external generalization. • SegFormer achieved the highest segmentation accuracy, reaching Dice scores of 0.93–0.96 for SE, EX, and HE on external validation. • Deformable DETR delivered the best detection performance, achieving external mAP values up to 0.895 across four lesion types. • Radiomics-driven classification using TES + TabPFN surpassed end-to-end ViT models, offering superior external accuracy (0.883) and AUC (0.947). • The combined transformer–radiomics framework provides a robust, interpretable, and clinically scalable solution for automated DR screening and severity assessment. To develop and evaluate a transformer-enabled multi-task framework for automated diabetic retinopathy (DR) analysis, including lesion-level segmentation and detection, and to compare end-to-end vision transformers with radiomics-based classification for DR severity grading across multi-center datasets. A total of 987 fundus images from two clinical centers were used for lesion segmentation and detection, and 6,852 images were used for four-class DR severity classification, with rigorous inclusion criteria and expert-verified annotations. Preprocessing included CLAHE normalization, artifact filtering, and standardized retinal masking. Four segmentation models (UNet++, CE-Net, Swin-UNet, SegFormer) and four detection models (RetinaNet, YOLOv11, DETR, Deformable DETR) were trained under harmonized settings. Classification was performed using two strategies: (1) an end-to-end Vision Transformer (ViT), and (2) a radiomics-based pipeline incorporating 971 IBSI-compliant radiomic features, ComBat harmonization, and three feature-selection methods (SGR, TES, mRMR) paired with six classifiers (CatBoost, LightGBM, TabPFN, SVM, RF, LR). All models underwent internal cross-validation and external multi-center testing. SegFormer achieved the highest segmentation performance, with Dice scores of 0.871–0.963 across lesions and strong external generalization. Deformable DETR achieved the best detection performance, reaching external mAP values up to 0.895. For severity classification, the radiomics-based TES + TabPFN pipeline achieved the best results, reaching an external accuracy of 0.883 and an AUC of 0.947, outperforming the ViT classifier (accuracy 0.838, AUC 0.902). Radiomics models demonstrated superior robustness under domain shift and reduced sensitivity to training-set size compared with end-to-end transformers. Transformer-based lesion analysis combined with radiomics-driven classification provides a robust, generalizable, and clinically meaningful solution for automated DR screening and severity assessment.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Multi-task transformer framework and radiomic signatures for multi-lesion segmentation, detection, and grading in diabetic retinopathy
Date Crossref
01/06/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Retinal Imaging and AnalysisRetinal Diseases and TreatmentsRadiomics and Machine Learning in Medical Imaging

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.