717: MULTIORGAN ULTRASOUND MODEL PREDICTS 48-HOUR EXTUBATION FAILURE: MULTICENTER PROSPECTIVE STUDY
Rattachement africain : ar, pl, ec, it, co, cl. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Introduction: Extubation fails in ~15–35% of ventilated ICU patients, and re-intubation worsens outcomes. Single-organ ultrasound studies exist, but integrated models are scarce. We hypothesized that a multiorgan ultrasound model would predict 48-hour extubation failure. Methods: Prospective multicenter study in 15 hospitals across 4 countries (ClinicalTrials.gov NCT06609798) with local IRB approvals and surrogate consent. Outcome: extubation failure within 48 hours. Centers were split by hospital into derivation (74%; n=255) and external validation (26%; n=86). Predictors included modified Lung Ultrasound Score (LUS); TAPSE, MAPSE, E/e′; diaphragmatic excursion and thickening fraction; BMI; and prespecified interactions. We fitted mixed-effects logistic regression (random patient intercept) and a tuned random forest. For the logistic model, bootstrap validation (300 replicates) preceded external validation. Discrimination was summarized by c-statistic; calibration by Cox slope and calibration-in-the-large (CITL). Clinical benefit was expressed as observed failure proportions in predefined high- versus low-risk strata. Results: We analyzed 341 extubations in 326 patients; 18.2% failed within 48 h. The final logistic model retained four interactions with explicit thresholds: TAPSE < 20 mm × diaphragmatic excursion < 14 mm (OR 2.38; 95% CI 1.21–4.69); MAPSE < 14 mm × E/e′ >15 (OR 3.59; 95% CI 0.82–15.77); LUS >6 × BMI (OR 1.01 per unit; 95% CI 0.99–1.04); MAPSE < 14 mm × BMI (OR 1.75; 95% CI 0.85–3.61). Bootstrap c-statistic was 0.65 (95% CI 0.56–0.74) with slope ≈1.02 and CITL -0.1; external c-statistic was 0.74 (0.59–0.90) with slope 1.05 (0.13–1.97) and CITL −0.51 (−1.17 to 0.14). With a 0.34 threshold (rule-in to defer extubation), 8.5% were high risk with 45% failures, versus 16% in low risk. The tuned random forest (30 trees; depth 1) achieved c-statistics of 0.70 (0.62–0.78) in derivation and 0.73 (0.59–0.88) in validation; at 0.24, 11.4% were high risk with 49% failures versus 14% in low risk. Conclusions: A multiorgan ultrasound model predicted 48-hour extubation failure with good calibration and discrimination. Risk stratification concentrated failures in the high-risk group while keeping failure rates lower in the low-risk group, supporting ultrasound-guided, risk-based extubation decisions.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- 717: MULTIORGAN ULTRASOUND MODEL PREDICTS 48-HOUR EXTUBATION FAILURE: MULTICENTER PROSPECTIVE STUDY
- Date Crossref
- 01/03/2026
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.