Aller au contenu principal
Accès ouvert déclaré 2026 article

Determination of High-Level Hexavalent Chromium in Chromium Slag Field Soils by Inductively Coupled Plasma-Optical Emission Spectrometry with Alkaline Extraction

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

The hexavalent chromium Cr(Ⅵ) content in chromium slag field soils typically ranges from tens to thousands of mg/kg, far exceeding the background values of ordinary soils and exhibiting complex matrices. Existing methods for determining high-level Cr(Ⅵ) in such contaminated sites are susceptible to matrix interferences. This study introduces a synergistic extraction method based on the industrial standard HJ 1082-2019 alkaline extraction solution, enhanced by the addition of EDTA chelating agent and Triton X-100 surfactant. This method improves extraction efficiency and suppresses Cr(Ⅲ) oxidation through dual mechanisms of chemical chelation and physical dispersion. Optimal extraction conditions, determined via orthogonal experiments, include: 12 mL alkaline extraction solution, 90℃ extraction temperature, 80 min extraction time, 3 mL Triton X-100, 12 mL EDTA, and a solid-to-liquid ratio of 1∶54 (g:mL). Under the optimal extraction conditions, the recovery rate of Cr(Ⅵ) in soil reached 96.8%, and the number of extractions was reduced from 6 times in the HJ 1082-2019 standard method to 2 times in this method. Cr(Ⅵ) quantification was performed using inductively coupled plasma-optical emission spectrometry (ICP-OES), with high-salt matrix interferences mitigated by adding 2.0 g of 001 × 7 strong acid cation exchange resin. The method exhibited excellent linearity (0−8.00 mg/L), a detection limit of 0.30 mg/kg, a quantification limit of 1.01 mg/kg, and an upper detection limit of 3200 mg/kg. Validation using certified reference materials [GBW(E)070255, RMH-A043] and two high-content Cr(Ⅵ) self-prepared samples demonstrated close agreement between measured and certified values (relative errors from −2.87% to −0.69%) and low relative standard deviations (RSD < 5.00%). Compared to flame atomic absorption spectrometry, this method offers superior matrix interference resistance and broader applicability, and has been successfully applied to Cr(Ⅵ) determination in soils from a chromium slag field in North China. The BRIEF REPORT is available for this paper at http://www.ykcs.ac.cn/en/article/doi/10.15898/j.ykcs.202503170047.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les sujets associés

Chromium effects and bioremediationHeavy metals in environmentAnalytical chemistry methods development

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.