Aller au contenu principal
Accès ouvert déclaré 2026 article

Permanent pacing via coronary sinus after tricuspid valve replacement: Keep bipolar coronary sinus leads on hand!

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : tr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Conduction disturbances requiring permanent pacemaker (PPM) implantation are common after tricuspid valve replacement (TVR). Conventional transvalvular right ventricular pacing carries a risk of prosthetic valve dysfunction, whereas epicardial pacing is limited by surgical complexity, high pacing thresholds, and reduced lead durability. Coronary sinus (CS) pacing represents a potential alternative; however, data following TVR remain limited. We retrospectively analyzed eight patients who underwent PPM implantation via the CS after TVR at our center. Demographic characteristics, procedural details, and pacing parameters were collected. Electrical performance (pacing threshold, lead impedance, and pacing percentage) was assessed during follow-up. PPM implantation via the CS was successfully performed in all patients (median age: 61 years; 87.5% female). Seven patients underwent bioprosthetic TVR and one underwent mechanical TVR. The median interval between surgery and PPM implantation was 7 days. Mean procedure and fluoroscopy times were 66.5 ± 25.2 minutes and 13.3 ± 6.8 minutes, respectively. No acute or periprocedural complications occurred. During a median follow-up of 20.5 months, pacing thresholds and lead impedance remained stable (median threshold: 1.5 V, IQR: 1.0–2.25; median impedance: 846 Ω, IQR: 470–979), with a median ventricular pacing percentage of 82%. No lead-related complications were observed. CS pacing is a feasible and safe strategy for patients requiring PPM implantation after TVR, providing stable electrical performance while avoiding the risks associated with transvalvular and epicardial leads. This approach may be particularly valuable in patients with mechanical prostheses and should also be considered in selected bioprosthetic valve recipients. Larger studies are required to confirm long-term outcomes. After a median follow-up of 20.5 months (IQR: 10-28), the median pacing threshold was 1.5 V (IQR: 1.0-2.25), the median impedance was 846 Ω (IQR: 470-979), and the pacing percentage was 82% (IQR: 24-100) (Table 3). In six patients, the CS lead was implanted in the lateral cardiac vein, while in two patients it was implanted in the anterior interventricular vein. No phrenic nerve capture was observed in any patient and no significant change in LVEF was 6 detected during follow-up (mean EF: 55.0 ± 5.5% vs. 56.4 ± 5.9%)

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Permanent pacing via coronary sinus after tricuspid valve replacement: Keep bipolar coronary sinus leads on hand!
Date Crossref
01/07/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac pacing and defibrillation studiesCardiac Valve Diseases and TreatmentsPain Management and Treatment

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.