Aller au contenu principal
2026 article

Hemolysis After Pulsed Field Ablation With a Variable‐Loop Irrigated Circular Catheter

0Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

INTRODUCTION: Hemolysis is a recognized complication of endocardial pulsed field ablation (PFA), and its severity is influenced by factors such as the number of applications, tissue contact, and characteristics of the PFA system. However, most existing data are based on the Pentaspline catheter, and limited information is available regarding hemolysis with other PFA systems. METHODS AND RESULTS: We evaluated hemolysis in seven consecutive patients with paroxysmal atrial fibrillation undergoing PFA using a variable-loop irrigated circular catheter (VLCC; Varipulse, Biosense Webster) and a dedicated generator (TRUPULSE). All procedures included pulmonary vein and posterior wall isolation, guided by a tissue proximity indicator (TPI). A median of 32 applications was delivered per patient. Plasma-free hemoglobin levels significantly increased from 0.01 (0.00-0.01) g/dL before the procedure to 0.05 (0.04-0.06) g/dL after the procedure (p < 0.001). Post-procedural reductions in hemoglobin levels and increases in bilirubin and lactate dehydrogenase levels were also observed, along with subnormal haptoglobin levels in 50% of patients. Creatine kinase levels increased significantly from 84 (82-146) U/L preoperatively to 323 (272-369) U/L postoperatively (p = 0.018). No cases of acute kidney injury occurred, and renal function remained stable post-procedure. CONCLUSION: This is the first study to evaluate hemolysis with a VLCC-based PFA using plasma-free hemoglobin as a biomarker. These findings underscore the importance of evaluating each PFA system individually to better understand their safety and biophysical effects.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Hemolysis After Pulsed Field Ablation With a Variable‐Loop Irrigated Circular Catheter
Date Crossref
17/03/2026
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Plasma Applications and DiagnosticsPlasma and Flow Control in AerodynamicsLaser-Ablation Synthesis of Nanoparticles

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.