Aller au contenu principal
Accès ouvert déclaré 2026 article

Simulation of water activation in the KATANA activation loop of the TRIGA reactor

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : si, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Water is widely used as a coolant in both fission and fusion nuclear reactors. However, when exposed to neutrons, it becomes activated and can turn into a significant radiation source especially in fusion reactors operating with deuterium–tritium plasma. This effect influences reactor design and requires accurate modeling to ensure safe and reliable operation. During the development of the ITER fusion reactor, methods and codes were created to simulate the process of water activation and its flow through the cooling system. However, lack of relevant experiments needed for experimental validation of these codes was highlighted. In 2024, the KATANA water activation facility began operating at the TRIGA Mark II reactor at the Jožef Stefan Institute with the aim to improve understanding of water activation and to validate computational tools used for simulating it. This paper presents an analysis of water activation in the KATANA loop using the open-source FLUNED code, which integrates fluid dynamics with neutron and gamma-ray transport simulations. The analysis focuses on activation calculations based on the latest loop design. Additionally, we examine how uncertainties in some of the main input parameters, i.e. flow rate and the total volume of the loop components, influence the overall uncertainty in the determined activity of water. • Fusion-relevant water activation studies in support of ITER operation. • CFD + FLUNED + MCNP: model water activation in KATANA’s closed loop. • Max saturation (short loop, 250 kW): 16 N: 7.1e7 Bq (0.5 L/s), 17 N: 1.2e4 Bq (0.8 L/s), 19 O: 1.1e7 Bq (0.1 L/s). • Corresponding dose rates: γ ( 16 N): 5.7 mSv/h; γ ( 19 O): 0.31 mSv/h; n( 17 N): 26 μ Sv/h. • Uncertainty from volume (0.05 L) and flow (0.001 L/s) < 1% for ⩾ 0.5 L/s.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Simulation of water activation in the KATANA activation loop of the TRIGA reactor
Date Crossref
01/06/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Nuclear reactor physics and engineeringNuclear Physics and ApplicationsParticle accelerators and beam dynamics

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.