Aller au contenu principal
Accès ouvert déclaré 2026 article

Physical Activity Traits From Wrist Sensors Correlate With Clinical Status in Pediatric Pulmonary Hypertension

0Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

ABSTRACT Physical activity (PA) estimated by a wearable sensor may reflect clinical status in pediatric pulmonary hypertension (PH). Prior studies used research‐grade hip‐anchored sensors or commercial wrist sensors with proprietary scoring algorithms. Wrist sensors may offer better acceptability in children; however, their ability to detect associations between PA and clinical characteristics is unknown. Youth 8–18 years with PH [Groups 1–4, functional class (FC) I‐II] and healthy controls wore a GENEActiv accelerometer on the non‐dominant wrist for 14 days. Raw acceleration data were processed using the open‐source GGIR R‐package. Participants completed a 6‐min walk distance (6MWD) and quality‐of‐life questionnaire. Muscle mass and strength were assessed by densitometry and handgrip dynamometry. The most recent cardiac testing was extracted from the medical record. Groups were compared by Fisher's exact test, unpaired t ‐test, or Wilcoxon rank sum test. Multivariate regression models assessed for associations between PA and clinical metrics. Thirty PH participants (median 13.9 years, 57% female, 57% Group 1, 50% FC I) and 29 controls were included. Total PA was similar. PH participants demonstrated fewer and shorter bouts of moderate‐to‐vigorous PA ≥ 10 min and more time spent at lower PA intensities. In PH participants, muscle mass was positively associated with PA but 6MWD was negatively associated with PA. PA was not associated with quality of life. Within the PH group, worse PA traits were associated with lower FC and worse clinical testing. Wrist sensors reveal deficits in PA traits including reduced moderate‐to‐vigorous activity bouts and lower intensity gradients in pediatric PH.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Physical Activity Traits From Wrist Sensors Correlate With Clinical Status in Pediatric Pulmonary Hypertension
Date Crossref
01/01/2026
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Pulmonary Hypertension Research and TreatmentsChronic Obstructive Pulmonary Disease (COPD) ResearchCardiovascular and exercise physiology

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.