Zero-contrast cardiac resynchronization therapy device implantation in heart failure patients with renal impairment
Résumé fourni par la source
BACKGROUND Coronary sinus (CS) venography is commonly used during cardiac resynchronization therapy (CRT) to guide left ventricular lead placement; however, iodinated contrast poses a substantial risk of contrast-induced acute kidney injury (CI-AKI) in patients with chronic kidney disease (CKD). Evidence supporting contrast-sparing CRT techniques remains limited. OBJECTIVE To assess the feasibility, safety, and renal outcomes of a zero-contrast CRT implantation strategy in CKD patients. METHODS Consecutive CKD patients (estimated glomerular filtration rate [eGFR] <60 mL/min/1.73 m 2 ) undergoing CRT at two centers between January 2023 and June 2025 were analyzed. Procedures were initiated using a contrast-free approach, with CS venography reserved as a bail-out strategy. Predictors of ≥20% eGFR decline were evaluated using multivariable logistic regression. Secondary outcomes included increase in left ventricular ejection fraction (LVEF) ≥5 percentage points at 3–6 months and one-year all-cause mortality and heart failure hospitalization (HFH). RESULTS Overall, 113 patients were analyzed. Zero-contrast implantation was successful in 57.5% of cases. Renal function remained stable after zero-contrast implantation (ΔeGFR +3.6 mL/min/1.73 m 2 ; p=0.08), whereas it declined significantly in the contrast group (−7.9 mL/min/1.73 m 2 ; p < 0.001). Post-procedural AKI occurred in 1.5% versus 14.6% of patients, respectively (p = 0.004). Contrast use (odds ratio 6.8, 95% confidence interval 1.5–30.9; p=0.013), lower baseline eGFR, and diabetes independently predicted a ≥20% decline in eGFR. Complication rates, LVEF improvement, and one-year mortality or HFH were similar between groups. CONCLUSION Zero-contrast CRT implantation is feasible, safe, and effective, with better renal preservation in patients with CKD.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Zero-contrast cardiac resynchronization therapy device implantation in heart failure patients with renal impairment
- Date Crossref
- 01/06/2026
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.