Aller au contenu principal
Accès ouvert déclaré 2026 review

Improved Safety of Nucleic Acid Amplification Technology Combined With Serological Tests for Screening Blood Donors: A Systematic Review and Meta‐Analysis

1Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : br. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

No laboratory test performed to date provides an absolute guarantee for detecting infectious agents. Nucleic acid amplification techniques/tests (NAT) associated with serological tests can increase safety and provide greater diagnostic accuracy for patients. We investigated the added safety of NAT technology combined with serological tests for screening blood donors for Hepatitis C virus (HCV), human immunodeficiency virus (HIV) and hepatitis B virus (HBV). Data were obtained from a systematic search conducted up until march 30, 2024 in five electronic databases: PubMed, Web of Science, Scopus, Embase, and the Cochrane library. Twenty-nine studies, published between 1998 and 2023, were included in the review. Notably, HBV infection was predominant among donors with positive NAT results, with 425 cases, including 373 with positive serology and 52 with negative serology. Data from the diagnostic window period (WP) indicated the highest number of HBV infection cases, with 154 reported. Of the 29 included studies, 10 reported cases of occult HBV infection and diagnostic WP infection. Thirteen studies identified donors during the occult HBV infection period, and 17 identified WP cases. Meta-analyses of positive NAT results following negative serological screening for HBV, HCV, and HIV revealed a significantly pooled frequency (p < 0.001). Positive NAT results retrieved from donors with negative serological HBV and HCV showed a significantly combined frequency (p < 0.001), while for HIV occurs the opposite (p = 0.085). For HBV, HBC and HIV serological tests and NAT-positive results, the pooled frequency was significantly (p < 0.001). The findings demonstrate the positive relationship and safety of molecular technology in screening blood donors for HBV, HCV, and HIV using serological tests. Molecular testing remains a valuable tool for detecting and elucidating bloodborne infections.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Improved Safety of Nucleic Acid Amplification Technology Combined With Serological Tests for Screening Blood Donors: A Systematic Review and Meta‐Analysis
Date Crossref
21/02/2026
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Hepatitis B Virus StudiesHepatitis C virus researchHIV Research and Treatment

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.