Short-Term Outcomes of Intra-Aortic Balloon Pump vs. Microaxial Flow Pump for Fulminant Myocarditis Supported by Venoarterial Extracorporeal Membrane Oxygenation
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: The clinical differences between intra-aortic balloon pumping (IABP) and a microaxial flow pump (Impella) for left ventricular (LV) unloading in patients with fulminant myocarditis (FM) supported with venoarterial extracorporeal membrane oxygenation (VA-ECMO) remain unclear. Methods and Results: In this single-center, retrospective cohort study, we analyzed 27 consecutive patients with lymphocytic FM who received VA-ECMO support. Patients were stratified by the LV unloading device that was used: IABP (n=15); or Impella (n=12). The primary endpoint was a composite of all-cause mortality or implantation of an extracorporeal ventricular assist device (exVAD) within 30 days of VA-ECMO initiation. Temporal changes in laboratory and hemodynamic parameters during the first 7 days of support were also assessed. Baseline characteristics, including LV ejection fraction (IABP 16% vs. Impella 18%; P=0.814) and QRS duration (139 vs. 105 ms; P=0.805), were comparable between groups. Nine patients met the primary endpoint (mortality [n=7]; exVAD implantation [n=2]). Kaplan-Meier analysis revealed a significantly lower incidence of the primary endpoint in the Impella group (log-rank P=0.018). The Impella group also showed a significantly greater improvement in cardiac power output (group×time interaction, P=0.040). Hemolysis, elevated total bilirubin, and increased serum creatinine were more pronounced in the Impella group. Conclusions: In patients with FM requiring VA-ECMO, LV unloading with Impella was associated with improved short-term clinical outcomes compared with IABP.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Short-Term Outcomes of Intra-Aortic Balloon Pump vs. Microaxial Flow Pump for Fulminant Myocarditis Supported by Venoarterial Extracorporeal Membrane Oxygenation
- Date Crossref
- 10/04/2026
- Éditeur
- Japanese Circulation Society
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.