Aller au contenu principal
Accès ouvert déclaré 2026 preprint

Quality versus quantity of training datasets for artificial intelligence–based whole liver segmentation

1Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Artificial intelligence (AI) based segmentation has many medical applications but limited curated datasets challenge model training; this study compares the impact of dataset annotation quality and quantity on whole liver AI segmentation performance. We obtained 3,089 abdominal computed tomography scans with whole-liver contours from MD Anderson Cancer Center (MDA) and a MICCAI challenge. A total of 249 scans were withheld for testing of which 30, MICCAI challenge data, were reserved for external validation. The remaining scans were divided into mixed-curation and highly-curated groups, randomly sampled into sub-datasets of various sizes, and used to train 3D nnU-Net segmentation models. Dice similarity coefficients (DSC), surface DSC with 2mm margins (SD 2mm), the 95th percentile of Hausdorff distance (HD95), and 2D axial slice DSC (Slice DSC) were used to evaluate model performance. The highly curated, 244-scan model (DSC=0.971, SD 2mm=0.958, HD95=2.98mm) performed insignificantly different on 3D evaluation metrics to the mixed-curation 2,840-scan model (DSC=0.971 [ p >.999], SD 2mm=0.958 [ p >.999], HD95=2.87mm [p>.999]). The 710-scan mixed-curation (Slice DSC=0.929) significantly outperformed the highly curated, 244-scan model (Slice DSC=0.923 [ p =0.012]) on the 30 external scans. Highly curated datasets yielded equivalent performance to datasets that were a full order of magnitude larger. The benefits of larger, mixed-curation datasets are evidenced in model generalizability metrics and local improvements. In conclusion, tradeoffs between dataset quality and quantity for model training are nuanced and goal dependent.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Quality versus quantity of training datasets for artificial intelligence–based whole liver segmentation
Date Crossref
18/02/2026
Éditeur
openRxiv
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

AI in cancer detectionAdvanced Radiotherapy TechniquesMedical Image Segmentation Techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.