Comparison of a Qualitative CMV PCR Kit Developed in a Laboratory Setting for Different Clinical Sample Types with the Reference Method
Rattachement africain : tr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: The aim of this study was to evaluate the clinical performance of an in-house qualitative CMV real-time PCR assay for the detection of cytomegalovirus (CMV) DNA in various non-plasma clinical sample types, in comparison with a commercial ref-erence method. Methods: In this prospective comparative study, 186 clinical sam-ples—including bronchoalveolar lavage fluid (BALF), stool, urine, colonoscopic biopsy, amniotic fluid, and intraocular fluid—were analyzed. A total of 166 samples with valid results from both test systems were included in the inter-method comparison. CMV DNA was detected using an in-house qualitative PCR assay in parallel with the reference method (artus® CMV QS-RGQ kit). Clinical performance was assessed using positive percent agreement (PPA), negative percent agreement (NPA), overall percent agreement (OPA), Cohen’s kappa coefficient (κ), and predictive values, in accordance with the CLSI EP12-A2 guideline for qualitative diagnostic tests. Results: When all clinical samples were evaluated collectively, good overall agreement was observed between the developed test and the reference method (κ = 0.66). High PPA, NPA, and kappa values were obtained for stool, urine, and invasive samples. In BALF samples, inter-method agreement was mod-erate, and the high NPV supported clinical exclusion of CMV infection. Predictive values varied according to the CMV DNA positivity rate of the analyzed sample groups. Conclusions: The laboratory-developed qualitative CMV PCR assay showed good inter-method agreement with a commercial reference method and appears suitable for qualitative CMV detection in non-plasma clinical specimens under routine laboratory conditions. The findings reflect comparative performance rather than gold-standard-based diagnostic accuracy or viral load quantification.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Comparison of a Qualitative CMV PCR Kit Developed in a Laboratory Setting for Different Clinical Sample Types with the Reference Method
- Date Crossref
- 10/02/2026
- Éditeur
- MDPI AG
- Type
- posted-content
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.