Feasibility and workflow analysis of confocal microscopy in robot‐assisted prostatectomy

2Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : at. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVES: To assess the diagnostic accuracy, workflow feasibility, and downstream compatibility of fluorescence confocal microscopy (Histolog® Scanner [HS]; SamanTree Medical SA, Lausanne, Switzerland) compared with frozen section (FS) for intraoperative margin evaluation (IME) during nerve-sparing robot-assisted radical prostatectomy (RARP). PATIENTS AND METHODS: Between May 2024 and April 2025, 68 patients undergoing RARP for non-metastatic prostate cancer were enrolled; two were excluded due to incomplete data, leaving 66 evaluable cases. The IME was performed using both HS and FS. HS images were interpreted intraoperatively by experienced uropathologists, while surgical decisions were based on FS results. The residual tissue following HS was assessed for compatibility with downstream immunohistochemistry (IHC) and next-generation sequencing (NGS). Diagnostic performance was evaluated against whole-mount histology as the reference standard. RESULTS: The HS identified carcinoma in four cases (three true positives, one false positive) and negative margins in 55 cases (53 true negatives, two false negatives); seven cases (10.6%) were classified as suspicious and resolved by FS. Considering only definite HS calls, sensitivity was 60.0%, specificity 98.1%, positive predictive value (PPV) 75.0%, and negative predictive value (NPV) 96.4%. When suspicious cases were treated as positive, sensitivity increased to 75.0%, specificity decreased to 91.4%, and PPV to 54.5%, while NPV remained 96.4%. HS processing did not impair IHC or NGS analyses. The overall R1 resection rate was 9.1%. CONCLUSION: Fluorescence confocal microscopy demonstrates high specificity and NPV for IME during RARP. A negative HS result can be interpreted with high confidence, potentially reducing the need for FS. Positive or suspicious HS findings should prompt targeted FS confirmation. Confocal laser scanning microscopy preserves tissue integrity for molecular testing and may be integrated into multimodal oncological workflows.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Feasibility and workflow analysis of confocal microscopy in robot‐assisted prostatectomy
Date Crossref
08/02/2026
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Medical University of Graz pays non établi dans la notice
    Université ou école supérieure

Medical University of Graz.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Prostate Cancer Diagnosis and TreatmentProstate Cancer Treatment and ResearchCutaneous Melanoma Detection and Management

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.