Aller au contenu principal
2025 article

Planimetry in aortic valve stenosis using computed tomography angiography - application in low gradient stenosis

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Aortic valve stenosis (AS) severity as assessed by transthoracic echocardiography (TTE) can remain inconclusive when flow velocity (Vmax), mean pressure gradient (∆Pm), and calculated valve area (cAVA) are non-congruent. In particular, the combination of an cAVA<1.0cm², Vmax <4.0 m/s and ∆Pm <40mmHg (low gradient (severe) aortic stenosis (LG(S)AS)) is frequently problematic. We suggest AVA by computed tomography angiography (CTA)-planimetry (pAVACTA) as a 4th severity criteria marker to aid classification. Objectives Defining the role of CTA-planimetry in LG(S)AS through integration of pAVACTA as 4th severity marker into the ESC/JASE flow-Charts for AS severity grading. Methods Patients who presented with a cAVATTE<1.0cm², Vmax<4m/s and ∆Pm<40mmHg to our institution and underwent a pre-TAVI-CTA-scan between 2012 and 2023 were included for analysis. The role of pAVACTA as a 4th severity marker was assessed by testing for AVA severity congruence between cAVATTE and pAVACTA. Based on data from a large cohort of patients with congruent severe AS (cAVATTE<1.0cm² & Vmax≥4m/s & ∆Pm≥40mmHg) we have recently proposed a pAVACTA cut-off of ≤0.95cm² to support and a pAVACTA ≥1.1cm2 to render unlikely the diagnosis of severe AS, with values in-between deemed indeterminate by planimetry. Results A total of 81 patients presented with LFLG-AS (Low Flow SVI SVI<35ml/m², LVEF≥50%) and 173 patients with NFLG-AS (Normal Flow SVI≥35ml/m²). Congruence between cAVATTE and pAVACTA was high in both groups at 82.7% and 76.3%, respectively, with non-congruence low at 2.5% and 6.4%. Conclusion In our cohort, CTA-based planimetry confirms AVA indicative of severe AS in a high percentage of patients with LG-AS irrespective of flow. Adding pAVACTA to the diagnostic work-up as a 4th severity criteria may by useful by adding diagnostic certainty.Proposed ESC Flow Chart Modification

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Planimetry in aortic valve stenosis using computed tomography angiography - application in low gradient stenosis
Date Crossref
01/11/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsAortic Disease and Treatment ApproachesCongenital Heart Disease Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.