Preclinical serial shear stress analysis of a novel strut-free fibrillated bioresorbable polymeric endoluminal graft
Rattachement africain : au, ie, nl, gb. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Aim To characterise near-wall haemodynamics immediately after implantation of a next-generation, strut-free biorestorative endoluminal graft, evaluate changes over 3 months during resorption, and assess whether early flow patterns may influence subsequent remodelling in two preclinical models. Methods Three rabbits and six mini-pigs underwent bilateral implantation of a resorbable fibrillated scaffold (RFS) in peripheral arteries. Intravascular optical coherence tomography (OCT) combined with angiography enabled generation of 29 case-specific three-dimensional reconstructions during a 3-month study period. Pulsatile, non-Newtonian computational fluid dynamics (CFD) quantified the endothelial shear stress (ESS). Results OCT demonstrated a continuous endoluminal surface consistent with the strut-free RFS design and revealed a distinct optical transition at the device boundary. Haemodynamic mapping showed low-ESS regions at scaffold edges and broadly unidirectional near-wall flow within the scaffolded segment. Quantitatively, ESS showed a modest, non-significant upward trend during follow-up before stabilising (rabbits: +0.37 Pa, p = 0.085; mini-pigs: +0.37 Pa, p = 0.091). Higher early ESS correlated with subsequent lumen gain ( ρ s = 0.50; p < 0.001), and serial analyses revealed an evolving association over time. Conclusion RFS implantation instated a largely homogeneous ESS profile that evolved with 3-month remodelling, consistent with a dynamic flow-healing interplay that warrants longer-term evaluation through full bioresorption.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Preclinical serial shear stress analysis of a novel strut-free fibrillated bioresorbable polymeric endoluminal graft
- Date Crossref
- 06/02/2026
- Éditeur
- Frontiers Media SA
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.