Abstract Background Quantitative myocardial blood flow (MBF) and myocardial flow reserve (MFR) provide incremental diagnostic and prognostic value in cardiac PET, but their widespread use is limited by the technical demands of dynamic imaging protocols. We evaluated the feasibility of using artificial intelligence (AI) to predict MBF and MFR from static and gated PET images, without the need for dynamic acquisition. Methods A machine learning (XGBoost) model was trained on 82Rb PET multi-center dataset using static perfusion imaging, injected dose, hemodynamic measures, clinical data and CT-derived features (including body composition) from the hybrid CT attenuation scan. Model performance was evaluated externally in an independent cohort. Results In total, 10,566 (derivation-cohort) and 7,842 (external-cohort) patients were included in this multi-center study. On the external-cohort, AI approach achieved an Area under the curve (AUC) of 0.92 (0.92–0.93) for abnormal stress MBF and 0.91 (0.90–0.92) for abnormal MFR; Intra-class correlation (ICC) 0.80 (0.78–0.82) and 0.78 (0.76–0.79), respectively. AI MFR closely mirrored the prognostic performance of measured MFR, showing nearly identical Kaplan–Meier risk stratification (both p<0.0001) and maintaining strong, and independently significant associations with all-cause mortality (HR 3.4 [2.8–4.2] vs. 4.6 [3.6–5.8]; both p<0.001), and demonstrated similar added value to perfusion for mortality prediction. Conclusion AI-predicted virtual stress MBF and MFR assessment using static and gated PET data is feasible and generalizable across cohorts. By removing the dependency on dynamic acquisitions, this approach has the potential to broaden the clinical adoption of flow quantification. STRUCTURED GRAPHICAL ABSTRACT PET: Positron Emission Tomography, CT: Computed Tomography, MFR: Myocardial Flow Reserve Key Question: Can machine learning models trained on dynamic PET datasets accurately predict regional stress myocardial blood flow (MBF) and myocardial flow reserve (MFR) from static image features, physiological parameters, and CT-based anatomical measures? Key Finding: Artificial intelligence can accurately estimate MBF and MFR from non-dynamic PET data, with strong agreement to reference standards. Take-home Message: By eliminating reliance on dynamic PET acquisitions, machine-learning has the potential to broaden clinical adoption of quantitative flow assessment.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Virtual myocardial blood flow and flow reserve from static PET imaging using artificial intelligence
Date Crossref
05/02/2026
Éditeur
openRxiv
Type
posted-content

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Cardiac Imaging and DiagnosticsMedical Imaging Techniques and ApplicationsRadiomics and Machine Learning in Medical Imaging

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.