Aller au contenu principal
2025 article

Planimetry in aortic valve stenosis using computed tomography angiography - cut-off determination

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Aortic valve (AV) stenosis is quantified by transthoracic echocardiography (TTE). However, stenosis severity can remain inconclusive when TTE severity parameters are incongruent. AV-area (AVA) by CTA-planimetry (pAVACTA) may aid in these cases. Objectives Defining the role of CTA-planimetry for tricuspid (TC) AV stenosis by cut-off determination. TTE of conclusive patients was used as Goldstandard. Methods Severity classification of AV stenosis was performed using TTE with classification into conclusive if all three of the following criteria were congruent: Vmax≥4m/s & ∆Pm≥40mmHg & cAVATTE<1.0cm² (3+ "severe", 3- "non-severe"). Retrospective, single center screening of 4059 pre-TAVI-CTA-scans (2012-2023) yielded 1161 conclusive TC cases. Cut-off values for pAVACTA as a 4th severity criteria marker were determined by first correlating pAVACTA to cAVATTE directly and second by comparing different pAVACTA values for predicting "severe" stenosis via receiver operator curve (ROC). Results pAVACTA showed strong positive correlation with cAVATTE (Pearson-Correlation 0.673, p<0.001) with Linear Regression yielding a correlating factor (contraction coefficient CC) of 0.91 (95% CI [0.895, 0.915], p<0.001). ROC analysis (AUC 0.888, p<0.001) yielded a cut-off range with severe stenosis "likely" at pAVACTA≤0.95cm² (Sens. 87%, Spec. 78.9% via Youden’s index) and "unlikely" at ≥1.1cm² (-LR 0.092 at <1.1cm²). Conclusion For a given pAVACTA the expected cAVATTE is smaller as the correlating factor (CC) is <1.0. Adding pAVACTA as a 4th AV-stenosis severity marker utilizing a newly defined cut-off range could aid decision making in patients with inconclusive TTE results. Further research is required to validate and narrow cut-off ranges and to test for clinical relevance.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Planimetry in aortic valve stenosis using computed tomography angiography - cut-off determination
Date Crossref
01/11/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsCoronary Interventions and DiagnosticsCongenital Heart Disease Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.