Abstract Background Aortic valve (AV) stenosis is quantified by transthoracic echocardiography (TTE). However, stenosis severity can remain inconclusive when TTE severity parameters are incongruent. AV-area (AVA) by CTA-planimetry (pAVACTA) may aid in these cases. Objectives Defining the role of CTA-planimetry for bicuspid (BC) AV stenosis by cut-off determination. TTE of conclusive patients with cut-off parameters established as Goldstandard for Tricuspid (TC) AVs was used as reference. Methods Severity classification of AV stenosis was performed using TTE with classification into conclusive if all three of the following criteria were congruent: Vmax≥4m/s & ∆Pm≥40mmHg & cAVATTE<1.0cm² (3+ "severe", 3- "non-severe"). Retrospective, single center screening of 4059 pre-TAVI-CTA-scans (2012- 2023) yielded 133 conclusive BC cases. Cut-off values for pAVACTA as a 4th severity criteria marker were determined by first correlating pAVACTA to cAVATTE directly and second comparing different pAVACTA values for predicting "severe" stenosis via receiver operator curve (ROC). Results pAVACTA showed strong positive correlation with cAVATTE (Pearson-Correlation 0.780, p<0.001) with Linear Regression yielding a correlating factor (contraction coefficient CC) of 0.84 (95% CI [0.810, 0.861], p<0.001). ROC analysis (AUC 0.895, p<0.001) yielded a cut-off range with severe stenosis "likely" at pAVACTA≤1.08cm² (Sens. 88.3%, Spec. 77.3% via Youden’s index) and "unlikely" at ≥1.2cm2 (-LR 0.091 at <1.20cm²). Having previously performed a similar analysis for TC Valves with resulting proposed pAVACTA cut-off values of ≤0.95cm² to support severe AS and ≥1.10cm2 to render it unlikely, direct comparison showed larger pAVACTA cut-off values for BC than TC Valves at a smaller CC (~0.84 vs ~0.91). Conclusion For a given pAVACTA the expected cAVATTE is smaller with this effect more pronounced in BC than in TC AVs. Cut-off values for pAVACTA as a 4th AV-stenosis severity marker should differentiate between BC and TC as hemodynamic impact depends on valve shape.Hemodynamic Effect of Valve Shape

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Planimetry in aortic valve stenosis using computed tomography angiography - bicuspid cut-off determination
Date Crossref
01/11/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsCoronary Interventions and DiagnosticsCardiovascular Function and Risk Factors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.