Fluoroscopy-guided catheter tip positioning optimization: 10–30 mm beyond landmarks is associated with reduced intrathoracic central venous stenosis risk in hemodialysis patients

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Introduction: The 2019 KDOQI guidelines recommend fluoroscopy-guided placement of tunneled cuffed catheter tips within the right atrium. However, fluoroscopy may misidentify the cavoatrial junction. This study quantified the discrepancy between digital subtraction angiography and fluoroscopy in locating the cavoatrial junction and assessed its impact on intrathoracic central venous stenosis risk. Methods: This retrospective cohort study analyzed 90 patients with right internal jugular tunneled cuffed catheters who underwent DSA at our hospital between June 2023 and May 2025; digital subtraction angiography and fluoroscopy were compared in locating the cavoatrial junction. Catheter tips were classified by DSA-defined location: superior vena cava upper segment (Group A), lower segment (Group B), or right atrium (Group C). Intrathoracic central venous stenosis risks were analyzed using logistic regression. Results: The DSA-defined cavoatrial junction was consistently 21.64 ± 7.23 mm caudal to fluoroscopic landmarks. The incidence of central venous stenosis was 34.4%. Intrathoracic central venous stenosis incidence was significantly higher in Group A versus C ( p < 0.0167) and Group B versus C ( p < 0.0167). Catheter tip location within the superior vena cava was associated with 5.78-fold higher odds of intrathoracic central venous stenosis compared to placement within the right atrium (OR = 5.78, 95% CI: 1.75–19.06; p = 0.004). Conclusion: Fluoroscopy overestimates the cavoatrial junction position. Given that right atrium placement reduces intrathoracic central venous stenosis risk, advancing the catheter tip 10–30 mm beyond fluoroscopically guided landmarks constitutes a key maneuver for achieving accurate positioning. Implementation of this optimization strategy is associated with a 5.78-fold reduction in odds of intrathoracic central venous stenosis, providing actionable optimization for hemodialysis access management.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Fluoroscopy-guided catheter tip positioning optimization: 10–30 mm beyond landmarks is associated with reduced intrathoracic central venous stenosis risk in hemodialysis patients
Date Crossref
06/02/2026
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Central Venous Catheters and HemodialysisVascular anomalies and interventionsHemodynamic Monitoring and Therapy

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.