Quantitative MRI Evaluation of Hemispheric Asymmetry in Circle of Willis Artery Diameters
Rattachement africain : nl, de. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: Previous studies have identified hemispheric asymmetries in cerebral blood flow and volume, favoring the left hemisphere. Accordingly, we hypothesized that arteries on the left side of the circle of Willis (CoW) are larger than on the right. We compared artery diameters between the hemispheres. METHODS: Cranial time-of-flight magnetic resonance angiography scans of 1052 participants from a population-based cohort were assessed. Diameters of major CoW arteries (> 1.2 mm) were measured using a semiautomatic tool (mean ± standard deviation) and compared between the left and right hemisphere using a paired-samples t-test. As the posterior communicating arteries (Pcom) are often small and non-normally distributed, they were measured manually, categorized as "present" (≥ 1 mm) or "aplastic/hypoplastic" (< 1 mm), and compared using odds ratios (OR) with 95% confidence intervals (CI). RESULTS: The A2 segment of the anterior cerebral artery was smaller on the left than on the right (1.97 ± 0.21 mm vs. 2.01 ± 0.22 mm; p < 0.001), while the vertebral artery (2.36 ± 0.44 mm vs. 2.25 ± 0.41 mm; p < 0.001) and P1 segment of the posterior cerebral artery (2.01 ± 0.28 mm vs. 1.98 ± 0.29 mm; p = 0.001) were larger on the left. The Pcom was less frequently present on the left (26.7%) than on the right (33.4%; OR 0.73, 95% CI 0.60-0.88). No left-right differences were found for the A1 segment, M1 segment of the middle cerebral artery, and internal carotid artery. CONCLUSIONS: We found that some vessels were larger in the left hemisphere, whereas others were smaller. Future studies should investigate underlying mechanisms driving these specific asymmetries.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Quantitative MRI Evaluation of Hemispheric Asymmetry in Circle of Willis Artery Diameters
- Date Crossref
- 01/01/2026
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Utrecht University pays non établi dans la noticeUniversité ou école supérieure
-
University Medical Center Utrecht pays non établi dans la noticeÉtablissement de santé
-
Universitätsmedizin Greifswald pays non établi dans la noticeÉtablissement de santé
-
Universität Greifswald pays non établi dans la noticeUniversité ou école supérieure
-
Institute For Diagnostic Radiology and Neuroradiology University Medicine Ernst Moritz Arndt University Greifswald Greifswald Germany pays non établi dans la noticeUniversité ou école supérieure
Utrecht University, University Medical Center Utrecht et Universitätsmedizin Greifswald, avec 2 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.