Aller au contenu principal
Accès ouvert déclaré 2026 article

High accuracy of knee alignment following well-balanced image-based robot-assisted total knee arthroplasty; radiographic validation of implant position and knee alignment

0Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : be. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Image based robotic assisted knee replacement surgery enables surgeons to achieve patient-specific alignment through intraoperative ligament balancing and implant positioning. The purpose of this study was to validate the accuracy of the implant position and lower limb alignment using full-leg weight-bearing postoperative radiographs. This retrospective study included 69 patients receiving total knee arthroplasty (TKA) with the use of a MAKO robot and patella-in-place balancer between 01/2023 and 04/2024. All patients received a Triathlon® CS prosthesis with functional alignment philosophy. Coronal parameters (mechanical hip-knee-ankle-angle (mHKA), lateral distal femoral angle (LDFA), and medial proximal tibial angle (MPTA)) and sagittal alignment parameters (femoral flexion and tibial slope) were collected from the intraoperative plan and compared with pre- and postoperative weight-bearing full leg radiographs (FLR). Preoperative mean mHKA of 2.4° ± 6.2° varus corrected to 2.2° ± 2.7° varus intraoperatively and 1.4° ± 3.2° varus postoperatively; with no significant differences intra-to postoperatively. LDFA increased significantly from 87.8° ± 3.2° to 90.1° ± 2.2° intraoperatively, but did not differ significantly on postoperative radiographs. Original MPTA angle was preserved intraoperatively at 87.7° ± 1.7°, but increased by 0.9° postoperatively (p = 0.005). Femoral flexion decreased after surgery from 5.8° ± 3.9° to 3.9° ± 2.8° (p < 0.001). Tibial slope decreased intraoperatively from 8.6° to 6.7° (p < 0.001), with no further postoperative change. Functional alignment philosophy in combination with a patella in place balancing device in reliably reproduced the targeted limb alignment and implant positioning, with postoperative measurements closely matching intra-operative values across all alignment subgroups. There was no soft-tissue laxity asymmetry detected that had meaningful effect on alignment outcomes, supporting this technique as a precise and consistent surgical strategy.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
High accuracy of knee alignment following well-balanced image-based robot-assisted total knee arthroplasty; radiographic validation of implant position and knee alignment
Date Crossref
01/05/2026
Éditeur
Scientific Scholar
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Total Knee Arthroplasty OutcomesOrthopaedic implants and arthroplastyKnee injuries and reconstruction techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.