Aller au contenu principal
2025 article

Persuing ventricular-arterial coupling: proposing a new cut-off of TAPSE/sPAP to identify patients with pulmonary hypertension after intermediate-high risk pulmonary embolism

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : pt. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Introduction – Pulmonary hypertension (PH) remains a potential long-term complication following pulmonary embolism (PE). Right heart catheterization (RHC) is the gold-standard for the diagnosis while echocardiography is often used as a non-invasive screening tool. The ventricular-arterial coupling accessed by echocardiography in the form of TAPSE/sPAP ratio is increasingly used as an add-on to other echocardiography parameters to better predict the probability of PH. This study aimed to evaluate the predictive power of echocardiographic parameters to detect PH in patients with intermediate-high risk PE submitted to catheter-directed therapy (CDT). Methods – Patients with intermediate-high risk PE submitted to catheter-directed therapy in a tertiary centre are submitted to a multimodality evaluation at 3 to 6-month follow-up to screen for PH. Patients were divided in two groups according to the presence of pre-capillary PH (mPAP >20 mmHg, PVR > 2 WU and PCWP < 15 mmHg in RHC) and echocardiographic parameters were analysed to assess their power to predict PH. Results – From the 78 patients, 42 completed the follow-up and were included in the analysis (median age 59 years [IQR 47-73 years], 57,1% female). 20 patients (47,6%) were diagnosed with PH by RHC at 3-6 month follow-up. Echocardiographic parameters of the right heart that were significantly different between the two groups were the presence of tricuspid regurgitation (p=0,01) and the TAPSE/sPAP ratio (p= 0,03). Peak tricuspid regurgitation velocity (p=0,169) and RVOT acceleration time (p=0,520) showed no statistically significant differences between the two groups. The ROC curve analysis of TAPSE/sPAP showed the best cut-off value of 0,64 (p=0,001, AUC 0,752, Sensitivity 53%, Specificity 93%) when comparing with the guideline recommended cut-off of 0,55 (p=0,389, AUC 0,577, Sensitivity 20%, Specificity 95%). A logistic regression model showed a OR 2,15 (p=0,017) in predicting PH for each increase of 0,1 in TAPSE/sPAP ratio. Conclusion – In our study, for patients after intermediate-high risk PE, the ventricular-arterial coupling accessed by echocardiogram (TAPSE/sPAP) showed to be most valuable echocardiographic parameter to predict the presence of PH 3 to 6 months of effective anticoagulation. However, the optimal cut-off may be outdated taking into account the most recent hemodynamic threshold for the diagnosis of PH. In our cohort, a higher value of TAPSE/sPAP ratio seems to be a better predictor of PH.ROC Curve

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Persuing ventricular-arterial coupling: proposing a new cut-off of TAPSE/sPAP to identify patients with pulmonary hypertension after intermediate-high risk pulmonary embolism
Date Crossref
01/11/2025
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Hospital de Santa Marta pays non établi dans la notice
    Établissement de santé

Hospital de Santa Marta.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Venous Thromboembolism Diagnosis and ManagementPulmonary Hypertension Research and TreatmentsHemodynamic Monitoring and Therapy

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.