Development and multicentre validation of an artificial intelligence electrocardiogram model for ventricular remodeling in repaired tetralogy of Fallot
Rattachement africain : us, de, ca. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Aims: Periodic cardiac MRI (CMR) is recommended to identify adverse ventricular remodelling in repaired tetralogy of Fallot (TOF), but access to CMR is uneven, and compliance is poor. We developed a 12-lead electrocardiogram (ECG) artificial intelligence (AI) biomarker to identify CMR-quantified adverse biventricular remodelling in repaired TOF. Methods and results: , RV ejection fraction (EF) <47%, and left ventricular EF <55%. Model discrimination, calibration, and net benefit as a screening test to rule out ventricular remodelling were assessed. Nine hundred and eight patients (2552 ECGs) were included in training, and 782 patients (1795 ECGs) in external validation (outcome prevalence 57%). The area under the receiver-operating curve (AUROC) was 0.85 (95% confidence interval 0.83-0.87), and average precision was 0.88. At a screening risk-threshold of 0.25, there was 92% sensitivity, 41% specificity, 87% negative predictive value, and 55% positive predictive value for ventricular remodelling, which yielded a 13% net reduction in CMR use on net benefit analysis. There was no difference by sex or race/ethnicity, but there were differences by age and site, with two of five sites with lower AUROC than the others, and three of five sites met criteria for miscalibration, which improved after centre-specific calibration. Conclusion: An artificial intelligence analysis of electrocardiogram (AI-ECG) biomarker in repaired TOF effectively identifies ventricular remodelling to inform timing of advanced imaging. Extensive external validation revealed variation in discrimination and calibration that are important considerations for clinical implementation and regulatory approval pathways of AI-ECG in congenital heart disease.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Development and multicentre validation of an artificial intelligence electrocardiogram model for ventricular remodeling in repaired tetralogy of Fallot
- Date Crossref
- 27/01/2026
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.