Aller au contenu principal
Accès ouvert déclaré 2026 article

Design and Evaluation of User-Centered Extended Reality Myoelectric Prosthesis Training Tool

0Citations signalées — pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

In recent years, extended reality-based myoelectric training has emerged as a promising approach to prepare users for advanced prosthesis control. This study: 1) identified User Needs for an ideal training tool through qualitative interviews with occupational therapists; 2) developed the Myoelectric Training in Extended Reality (MyoTrainXR) system; and 3) evaluated its usability using an advanced postural control strategy. Six individuals with intact limbs and two with trans-radial upper limb loss underwent four 45-minute training sessions with the Block Builder module. The Pasta Box Task was used during training and evaluation, and the Cup Transfer Task was used only during evaluation. In the Pasta Box Task, participants with intact limbs maintained a 100% completion rate, while their success rate increased from $86.1\pm 5.8$ % to $98.5\pm 3.7$ %. Participants with upper limb loss began with completion rates between 0% and 40%, improving to 100%, with success rates between 90.9% and 100% by the final evaluation. Iteration completion times showed significant reduction across all participants ( $p$ -value < 0.05, linear mixed-effects model), with the median decreasing from 19.4 to 15.8 seconds. The Cup Transfer Task showed a similar trend of significant improvement, demonstrating that the acquired skills generalized to an untrained task. The system also demonstrated excellent usability, with an average System Usability Scale score of $81.9\pm 10.0$ . These findings indicate that our user-centered extended reality training tool holds promise for enhancing myoelectric control proficiency.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Design and Evaluation of User-Centered Extended Reality Myoelectric Prosthesis Training Tool
Date Crossref
01/01/2026
Éditeur
Institute of Electrical and Electronics Engineers (IEEE)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Muscle activation and electromyography studiesProsthetics and Rehabilitation RoboticsStroke Rehabilitation and Recovery

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.