Aller au contenu principal
Accès ouvert déclaré 2026 article

Safety, performance, and remote programming utilization of an insertable cardiac monitor: The LUX-Dx PERFORM study

0Citations signalées — pas une note de qualité
10Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

Background: Insertable cardiac monitors (ICMs) are designed to record subcutaneous electrocardiographic data for the diagnosis and management of arrhythmias. Objective: The LUX-Dx PERFORM study evaluated the safety of the LUX-Dx ICM, the utilization of remote reprogramming, and the performance of the LUX-Dx arrhythmia detection algorithms. Methods: The study included 727 patients with multiple indications for an ICM including atrial fibrillation management, syncope, and cryptogenic stroke. The primary safety endpoint was evaluated via 30-day and 12-month ICM system-related complication-free rates. Device programming changes were quantified by type and impact on episode detections. A subset of 601 patients was enrolled in a 14-day Holter study to evaluate the performance of the ICM against a third-party extended Holter monitor patch. Results: ICM implants occurred in hospital (n = 547; 76%) and clinic settings (n = 170; 24%) with an extremely low 12-month complication rate (n = 3; 0.4%). Device reprogramming was performed on 184 patients (26%), with 82% of programming changes occurring remotely. Programming adjustments to reduce or enhance device detections led to an approximately 2-fold decrease or increase in monthly episodes, respectively. In the Holter substudy, the LUX-Dx identified 23 patients with atrial fibrillation episodes that were not detected by the extended Holter monitor and demonstrated 100% sensitivity for detecting pause episodes. Conclusion: Fewer than 1 in 200 patients had a complication within 1 year of ICM implant, and the LUX-Dx ICM demonstrated strong arrhythmia detection performance relative to an industry-standard patch monitor. Remote programming was frequently used, which may enhance detection and streamline data processing and care in the device clinic. Study Identifier: NCT04732728.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Safety, performance, and remote programming utilization of an insertable cardiac monitor: The LUX-Dx PERFORM study
Date Crossref
01/04/2026
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Healthcare Technology and Patient MonitoringCardiovascular Syncope and Autonomic DisordersCardiac pacing and defibrillation studies

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.